Eaton xEffect MCB, 2P, 2A Curve C, 240 → 415V AC, 10 kA Breaking Capacity

Subtotal (1 unit)*

₩130,453.20

Add to Basket
수량 선택 또는 입력
재고있음
  • 21 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩130,453.20

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
847-3298
제조사 부품 번호:
278748 FAZ-C2/2
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Number of Poles

2

Current Rating

2A

Tripping Characteristics

Type C

Rated AC Voltage

240 → 415V

Breaking Capacity at Maximum Voltage Rating

10 kA

Range

xEffect

Circuit Breaker Type

MCB

Width

85mm

Length

36mm

Mounting Style

DIN Rail Mount

Depth

73mm

Model Number

FAZ-C2/2

Eaton FAZ Series Circuit Breakers


The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eaton’s FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.

Features and Benefits


• The Eaton miniature circuit breaker has a current limiting design, providing short circuit interruption to reduce let-through energy, which can damage the circuit.
• Rated currents up to 63A.
• The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
• Reliable and safe operation with six levels of thermal-magnetic over-current protection.
• Red or green light indicates the contact position.
• Easy installation.
• Suitable for supplementary protection.

Eaton xEffect Mini Circuit Breaker, 2 A, 2 Pole - FAZ Series - FAZ-C2/2


This mini circuit breaker (MCB) from Eaton's FAZ series is a reliable way to prevent damage to an electrical circuit caused by overload or short circuits. As it's a C-Curve MCB, it can stop an electric current of five to ten times the rated amount of 2 A. This means that it's a good choice for protecting devices that operate at relatively low currents. You'll commonly find this type of circuit breaker used with fluorescent lighting or induction motors.

• Double poles provide protection for two circuits
• Trip-free mechanism prevents the breaker from being held in the 'on' position for added safety
• Robust polyurethane body for durability and excellent electrical insulation
• Compact dimensions of 36 (length) x 84.7 (width) x 72.6 mm (depth) for use in areas where space is limited

Why should I use an MCB instead of a fuse?


MCBs are safer and more reliable than fuses. They can also be reset for repeated use, whereas fuses need to be replaced in the event of overload or short circuits.

Note

Eaton formerly known as Moeller