Eaton xEffect xEffect Miniature Circuit Breaker, 3-Pole, 20 A, Type B, 415 V AC, 10 kA Breaking Capacity

Subtotal (1 unit)*

₩153,201.20

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 2월 10일 부터 3 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩153,201.20

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
847-3153
제조사 부품 번호:
278848 FAZ-B20/3
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Number of Poles

3

Product Type

Miniature Circuit Breaker

Current Rating

20 A

Tripping Characteristics

Type B

Rated AC Voltage

415 V

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

xEffect

Series

xEffect

Terminal Type

Twin-Purpose Terminal

IP Rating

IP20

Standards/Approvals

No

Width

73 mm

Depth

73mm

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Toggle Switch

Break Time

Instantaneous

Eaton 3-Pole MCB, 20A Current Rating, B Curve - FAZ Series - 278848 FAZ-B20/3


Features & Benefits

• Easy to snap onto a DIN rail for quick and convenient installation

• Meets IEC 60947-2 safety standards for circuit breakers used in low-voltage electrical power distribution systems

• Protected against impact and vibration, so is suitable to use in demanding settings

• Slim mounting width per pole of 17.5mm for maximum packing efficiency in a control cabinet

What does trip curve mean?


The trip curve of a circuit breaker refers to the strength of an overcurrent that the device can safely break.

Do I have to replace this MCB once it's tripped?


No, this MCB is manually re-settable, so there's no need to replace it once it's tripped.

Eaton FAZ Series Circuit Breakers


The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eaton’s FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.

Features and Benefits


• The Eaton miniature circuit breaker has a current limiting design, providing short circuit interruption to reduce let-through energy, which can damage the circuit.

• Rated currents up to 63A.

• The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.

• Reliable and safe operation with six levels of thermal-magnetic over-current protection.

• Red or green light indicates the contact position.

• Easy installation.

• Suitable for supplementary protection.

Note

Eaton formerly known as Moeller

관련된 링크들