Eaton xEffect MCB, 2P, 16A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- RS 제품 번호:
- 847-3147
- 제조사 부품 번호:
- 278734 FAZ-B16/2
- 제조업체:
- Eaton
Subtotal (1 unit)*
₩94,338.40
재고있음
- 추가로 2025년 12월 29일 부터 6 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩94,338.40 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 847-3147
- 제조사 부품 번호:
- 278734 FAZ-B16/2
- 제조업체:
- Eaton
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Eaton | |
| Number of Poles | 2 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 240 → 415V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Width | 85mm | |
| Length | 36mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 73mm | |
| Model Number | 278734 | |
| Application | Commercial, Residential | |
| 모두 선택 | ||
|---|---|---|
브랜드 Eaton | ||
Number of Poles 2 | ||
Current Rating 16A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 240 → 415V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Width 85mm | ||
Length 36mm | ||
Mounting Style DIN Rail Mount | ||
Depth 73mm | ||
Model Number 278734 | ||
Application Commercial, Residential | ||
Eaton FAZ Series Circuit Breakers
The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eatons FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.
Features and Benefits
The Eaton miniature circuit breaker has a current limiting design, providing short circuit interruption to reduce let-through energy, which can damage the circuit.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Eaton 2-Pole MCB, 16A Current Rating, B Curve - FAZ Series - 278734 FAZ-B16/2
Features & Benefits
• Needs only a small mounting width per pole of 17.5mm for maximum packing efficiency on a DIN rail
• Nylon housing resists corrosion, so is compatible with moist operating conditions
• Easy trouble-shooting, thanks to its colour-coded status indicator
• Captive screw terminals to help reduce the chance of screws being lost when they're unfastened
• Nylon housing resists corrosion, so is compatible with moist operating conditions
• Easy trouble-shooting, thanks to its colour-coded status indicator
• Captive screw terminals to help reduce the chance of screws being lost when they're unfastened
What's the difference between a B-curve and a C-curve circuit breaker?
A B-curve breaker like this one is suitable for tripping small current surges, reacting at 3 to 5 times its rated current. A C-curve device safeguards against larger surges and trips at 5 to 10 the current rating.
Note
Eaton formerly known as Moeller
관련된 링크들
- Eaton xEffect MCB, 3P, 16A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB Mini Circuit Breaker2P, 20A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 50A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 13A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- Eaton xEffect MCB, 3P, 25A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 25A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- Eaton xEffect MCB, 2P, 15A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- Eaton xEffect MCB, 3P, 13A Curve B, 240 → 415V AC, 10 kA Breaking Capacity