Siemens SENTRON 5SY4 Miniature Circuit Breaker, 2-Pole, 4 A, Type D, 400 V ac AC, 60 V dc DC, 10 kA Breaking Capacity

Subtotal (1 unit)*

₩137,522.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 3월 23일 부터 6 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩137,522.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
772-1284
제조사 부품 번호:
5SY4204-8
제조업체:
Siemens
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Siemens

Number of Poles

2

Product Type

Miniature Circuit Breaker

Tripping Characteristics

Type D

Breaking Capacity

10kA

Mount Type

DIN Rail

Range

SENTRON

Series

5SY4

IP Rating

IP20

Standards/Approvals

IEC/EN 60898-1, IEC/EN 60947-2/UL1077

Depth

76mm

Height

90mm

COO (Country of Origin):
DE

Siemens 5SY4 Series Miniature Circuit Breaker, 4A Current, 400V Rated AC Voltage - 5SY4204-8


This miniature circuit breaker provides overcurrent protection for AC and DC installations, delivering selective interruption for two-pole circuits on a DIN rail. Designed for industrial and infrastructure environments, it operates at up to 400V AC or 60V DC and uses a Type D tripping characteristic suitable for circuits with high inrush currents.

Features & Benefits


• 10kA breaking capacity for EN60898-rated short-circuit protection
• Rated current 4A to protect low-current branch circuits
• Type D tripping to tolerate high motor or transformer inrushes
• Screw terminals with 2.5 to 3.5N·m torque for secure conductor connections
• 2-pole configuration enabling simultaneous disconnection of both conductors
• IP20 touch protection while mounted with conductors connected

Applications


• Suitable for motor starter protection in factory automation panels
• Ideal for transformer secondary circuits with high inrush currents
• Used for selective protection in distribution boards of industrial sites
• Can be used for DC control circuits up to 60V in machinery cabinets

What conductor sizes can be connected to the device?


Solid and stranded conductors from 0.75mm² up to 35mm² are supported, with finely stranded conductors accepted up to 25mm²

AWG range is 18 to 4.

How does ambient temperature affect the rated current?


The nominal 4A rating varies with temperature: approximate operational currents are 3.76A at 40°C, 3.5A at 50°C, 3.36A at 55°C and 3.22A at 60°C.

What mechanical endurance can be expected from the breaker?


The device typically endures around 10,000 mechanical operating cycles under normal use.

Which installation positions and mounting methods are possible?


It can be mounted in any orientation on a DIN rail using a quick assembly system and occupies two modular width units.

What environmental limits apply during storage and operation?


Operational ambient range is −40°C to 70°C and storage range is −40°C to 75°C, with vibration resistance per IEC 60068-2-6.