Eaton xEffect MCB, 2P, 6A Curve C, 230 → 400V AC, 6 kA Breaking Capacity
- RS 제품 번호:
- 769-4719
- 제조사 부품 번호:
- 239100 FAZ6-C6/2
- 제조업체:
- Eaton
가격 개당**
₩98,971.60
16 <재고있음> 5-9영업일내 홍콩 발송*
* 배송 날짜는 선택한 수량과 배송 주소에 따라 달라질 수 있습니다.
수량 | 한팩당 |
---|---|
1 + | ₩98,971.60 |
**다른 단위에 대한 가격 표시
- RS 제품 번호:
- 769-4719
- 제조사 부품 번호:
- 239100 FAZ6-C6/2
- 제조업체:
- Eaton
- COO (Country of Origin):
- RO
Type C MCB's
Professional range of FAZ6 series miniature circuit breakers (MCBs) from Eaton. These Type C circuit breakers are designed for use with residential applications. FAZ6 series MCBs are available with either 1, 2, 3 or 4 pole with an instantaneous release response current of 5-10In. All models are highly reliable and excellent quality.
Features and Benefits
Thermal-magnetic overcurrent protection
Power to the miniature circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. MCB module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by Type B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Available in single pole up to 4 pole
Dual rating for IEC 60947-2 standard
MCB Module widths: 1P 17.5mm, 2P 35mm and 3P 52.5mm
Power to the miniature circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. MCB module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by Type B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Available in single pole up to 4 pole
Dual rating for IEC 60947-2 standard
MCB Module widths: 1P 17.5mm, 2P 35mm and 3P 52.5mm
Standards
IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar installations. In the UK these are traditionally known as miniature circuit breakers (MCBs), moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar installations. In the UK these are traditionally known as miniature circuit breakers (MCBs), moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
What are the differences between the Tripping Curves?
Type B: Instantaneous trip when the electrical current through the device is 3 to 5 times the rated current. The type B trip curve MCBs are designed for standard circuit protection, typically protection of generators, persons and very long cables
Type C: Instantaneous trip when the flow-through current is 5 to 10 times the rated current.
Type C trip curve residential and domestic MCBs are used for higher inrush currents such as in machines and lighting, providing overload protection of circuits and other consumer units.
Type D: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
D curve MCBs are suitable for inductive and capacitive loads like transformers condensers. and electric motors.
Type K: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
Type K curve MCBs are suitable for inductive loads like transformers, condensers. and electric motors.
Type S: Instantaneous trip when the flow-through current is 13 to 17 times the rated current.
Suitable for applications where high levels of inrush current are expected. The high magnetic trip point of type S curve MCBs prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies.
Type Z: Instantaneous trip when the flow-through current is 2 to 3 times the rated current.
Z curve MCBs are intended for use in electrical circuits that require a very low short circuit trip setting, for example, semiconductors.
Type C: Instantaneous trip when the flow-through current is 5 to 10 times the rated current.
Type C trip curve residential and domestic MCBs are used for higher inrush currents such as in machines and lighting, providing overload protection of circuits and other consumer units.
Type D: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
D curve MCBs are suitable for inductive and capacitive loads like transformers condensers. and electric motors.
Type K: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
Type K curve MCBs are suitable for inductive loads like transformers, condensers. and electric motors.
Type S: Instantaneous trip when the flow-through current is 13 to 17 times the rated current.
Suitable for applications where high levels of inrush current are expected. The high magnetic trip point of type S curve MCBs prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies.
Type Z: Instantaneous trip when the flow-through current is 2 to 3 times the rated current.
Z curve MCBs are intended for use in electrical circuits that require a very low short circuit trip setting, for example, semiconductors.
Eaton xEffect Mini Circuit Breaker, 6 A, 2 Pole - FAZ Series - FAZ-C6/2
Need a reliable way to prevent damage to your circuits? This mini circuit breaker (MCB) from Eaton protects your equipment in the event of a short circuit or overload. It's suitable for powerful electrical devices that are vulnerable to high surges of current, as it's a C-Curve MCB. This means it automatically stops currents of five to ten times the device's current rating of 6 A. Find this dependable device used in a range of commercial and industrial applications, from electric motors to fans.
• Wide operating AC voltage range of 230 to 400 V for use in a variety of high-voltage applications
• Two poles to protect two circuits for added versatility
• Compact dimensions of 80 (length) x 17.5 (width) x 61.5 mm (depth) to save space
• Trip-free safety mechanism to ensure contacts remain open in the event of an electrical fault
• Two poles to protect two circuits for added versatility
• Compact dimensions of 80 (length) x 17.5 (width) x 61.5 mm (depth) to save space
• Trip-free safety mechanism to ensure contacts remain open in the event of an electrical fault
When should I use a C-Curve MCB?
A C-Curve MCB is suitable for protecting circuits with high inrush and peak currents. It should be used for applications where the expected flow-through current will not exceed ten times the rated amount.
Note
Eaton formerly known as Moeller
FAZ MCB's
속성 | 값 |
---|---|
Number of Poles | 2P |
Current Rating | 6A |
Tripping Characteristics | Type C |
Rated AC Voltage | 230 → 400V |
Breaking Capacity at Maximum Voltage Rating | 6 kA |
Range | xEffect |
Circuit Breaker Type | MCB |
Width | 17.5mm |
Length | 80mm |
Mounting Style | DIN Rail Mount |
Depth | 62mm |
Model Number | FAZ6-C6/2 |