ABB SMISSLINE TP S400M Miniature Circuit Breaker, 4-Pole, 16A, Type K, 415V ac AC, 52.20 kA Breaking Capacity

Subtotal (1 unit)*

₩476,500.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2027년 1월 04일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩476,500.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
246-2686
제조사 부품 번호:
2CCS573103R8467
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Number of Poles

4

Product Type

Miniature Circuit Breaker

Current Rating

16A

Tripping Characteristics

Type K

Rated AC Voltage

415V ac

Breaking Capacity

52.20kA

Range

SMISSLINE TP

Series

S400M

Terminal Type

Screw

IP Rating

IP20

Width

72mm

Standards/Approvals

IEC/EN 60947-2

Height

91mm

Depth

75mm

Tripping Mechanism

Electromechanic, Thermal

Reset Actuator Type

I/O Actuator

COO (Country of Origin):
CH

ABB S400M Series Miniature Circuit Breaker, 16A Current, 415V Rated AC Voltage - 2CCS573103R8467


This miniature circuit breaker provides overcurrent protection for low-voltage installations and is intended for four-pole distribution circuits. It operates within three-phase systems at rated AC voltages up to 415V and uses a combined thermal and electromechanical trip arrangement to interrupt fault currents. The device is suited to panel mounting where standardised protection and a Compact footprint are required.

Features and Benefits:


• 52.20kA breaking capacity protects against high fault currents
• Type K tripping characteristic handles motor-start and inductive loads
• 4-pole configuration enables simultaneous multi-phase disconnection
• 16A current rating supports moderate load circuits
• I/O reset actuator permits clear manual on/off operation

Applications


• Suitable for three-phase distribution panels in commercial buildings
• Ideal for circuits with frequent motor starts and inductive loads
• Used with switchboards requiring coordinated multi-pole protection
• Can be used for feeder protection where high interrupting capacity is needed

What earth and enclosure protection level does it provide?


The enclosure meets IP20 protection, which guards against access to hazardous parts and solid objects larger than 12 mm.

How are the conductors terminated?


Conductors connect via screw terminals designed for secure clamping under vibration.

What standards guide its short-circuit performance?


Short-circuit interruption and design align with IEC/EN 60947-2 requirements.

Which mechanism initiates trip under overload and short-circuit?


Thermal action responds to prolonged overload while the electromechanical release trips on Rapid fault currents.

관련된 링크들