Better World
ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 100A, Type B, 400V ac AC, 6 kA Breaking Capacity
- RS 제품 번호:
- 237-3234
- 제조사 부품 번호:
- 2CDS252001R0825 S202-B100 6kA
- 제조업체:
- ABB
Subtotal (1 unit)*
₩216,372.00
재고있음
- 4 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩216,372.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS 제품 번호:
- 237-3234
- 제조사 부품 번호:
- 2CDS252001R0825 S202-B100 6kA
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Number of Poles | 2 | |
| Product Type | Miniature Circuit Breaker | |
| Current Rating | 100A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 400V ac | |
| Breaking Capacity | 6kA | |
| Mount Type | DIN Rail | |
| Range | System Pro M Compact | |
| Series | S200 | |
| Terminal Type | Screw | |
| IP Rating | IP40, IP20 | |
| Depth | 69mm | |
| Height | 88mm | |
| Width | 35mm | |
| Standards/Approvals | IEC/EN 60947-2, IEC/EN 60898-1 | |
| Better World Product | Yes | |
| Better World Claim | Designed for Disassembly | |
| Tripping Mechanism | Thermomagnetic, Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Number of Poles 2 | ||
Product Type Miniature Circuit Breaker | ||
Current Rating 100A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 400V ac | ||
Breaking Capacity 6kA | ||
Mount Type DIN Rail | ||
Range System Pro M Compact | ||
Series S200 | ||
Terminal Type Screw | ||
IP Rating IP40, IP20 | ||
Depth 69mm | ||
Height 88mm | ||
Width 35mm | ||
Standards/Approvals IEC/EN 60947-2, IEC/EN 60898-1 | ||
Better World Product Yes | ||
Better World Claim Designed for Disassembly | ||
Tripping Mechanism Thermomagnetic, Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- DE
ABB S200 Series Miniature Circuit Breaker, 100A Current, 400V AC Rated Voltage - 2CDS252001R0825 S202-B100 6kA
This miniature circuit-breaker provides overcurrent protection for low-voltage distribution systems and mounts on DIN-rail installations. It combines thermal and electromagnetic tripping to interrupt fault currents up to 6 kA and is intended for two-pole switching in three-phase or single-phase assemblies at rated AC voltages.
Features & Benefits
• 100A rating delivers high continuous current handling
• 6 kA breaking capacity limits fault-energy exposure
• Type B tripping offers sensitive protection for resistive loads
• Thermomagnetic and electromagnetic trip mechanisms separate overload and short-circuit responses
• Screw terminals permit secure conductor connection
• 35mm width enables Compact installation on DIN rail
• 6 kA breaking capacity limits fault-energy exposure
• Type B tripping offers sensitive protection for resistive loads
• Thermomagnetic and electromagnetic trip mechanisms separate overload and short-circuit responses
• Screw terminals permit secure conductor connection
• 35mm width enables Compact installation on DIN rail
Applications
• Suitable for motor-control circuits requiring fast short-circuit response
• Ideal for distribution boards in industrial automation panels
• Used with control cabinets needing two-pole isolation at 400V AC
• Can be used for protection of lighting and resistive heating loads
• Suitable for retrofit projects where a Compact footprint is required
• Ideal for distribution boards in industrial automation panels
• Used with control cabinets needing two-pole isolation at 400V AC
• Can be used for protection of lighting and resistive heating loads
• Suitable for retrofit projects where a Compact footprint is required
What mounting method is used for installation?
It clips directly onto a DIN rail for standard panel mounting.
What ingress protection is offered for panel environments?
The device provides IP20 protection for the terminals and IP40 for the front, limiting access to live parts.
How does the trip behaviour differentiate overloads from faults?
A bimetal element handles gradual overloads thermally while an electromagnetic trip responds instantaneously to high fault currents.
What pole configuration and voltage rating apply?
It is a two-pole breaker rated for operation at up to 400V AC.
관련된 링크들
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 6A, Type B, 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 3-Pole, 100A, Type B, 440V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 80A, Type K, 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 25A, Type B, 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 63A, Type B, 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 40A, Type B, 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 10A, Type B, 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 100A, Type C, 440V ac AC, 110 V dc DC, 6 kA Breaking