ABB System Pro M Compact SU200M MCB, 1P, 6A Curve K, 277V AC, 277V DC, 15 kA Breaking Capacity

Subtotal (1 Box of 1 unit)*

₩98,683.08

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 3월 16일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
Box(es)
Per Box
1 +₩98,683.08

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
231-9717
제조사 부품 번호:
2CDS271337R0377 SU201M-K6
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Number of Poles

1

Current Rating

6A

Tripping Characteristics

Type K

Rated AC Voltage

277V

Rated DC Voltage

277V

Breaking Capacity at Maximum Voltage Rating

15 kA

Range

System Pro M Compact

Series

SU200M

Circuit Breaker Type

MCB

Length

111mm

Width

17.5mm

Mounting Style

DIN Rail Mount

Depth

69mm

Model Number

SU201M-K6

Terminal Contact Type

Screw

Reset Actuator Type

Toggle Switch

COO (Country of Origin):
BG

ABB SU200M Series MCB, 1 Pole, 6A Current Rating - 2CDS271337R0377 SU201M-K6


This miniature circuit breaker is crafted for effective branch circuit protection in both AC and DC applications. Its universal compatibility enables use across various global markets. As part of the System pro M Compact series, this device delivers essential safety features to protect electrical systems from overloads and short circuits.

Features & Benefits


• High breaking capacity of 10 kA for improved safety
• Certified for use in AC and DC applications
• Clear contact position indication enhances operational awareness
• Rated current of 6A accommodating various electrical requirements
• Type K characteristics for specific tripping behaviour
• Designed for straightforward DIN rail mounting

Applications


• Utilised in residential electrical systems for effective protection
• Suitable for commercial installations requiring trustworthy circuit integrity
• Applicable for industrial machinery and automation systems

What should be considered during installation?


Ensure proper mounting on a DIN rail and adherence to electrical standards.

How often does maintenance need to be performed?


Regular inspections are recommended to verify functionality and avert accidental tripping.

Can it be used in extreme temperatures?


Yes, it operates within a temperature range of -25°C to +55°C.

What are the potential consequences of not using a circuit breaker?


Absence of a circuit breaker may result in equipment damage and heightened risk of electrical fires due to overload conditions.

How does it indicate a fault condition?


The circuit breaker provides clear contact position indication with red for ON and green for OFF.

관련된 링크들