ABB System Pro M Compact S200 MTUC MCB, 1P, 1A Curve C, 266V AC, 250V DC, 10 kA Breaking Capacity

Subtotal (1 Box of 1 unit)*

₩213,524.76

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 1월 30일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
Box(es)
Per Box
1 +₩213,524.76

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
231-9703
제조사 부품 번호:
2CDS271065R0014 S201MT-C1U
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Number of Poles

1

Current Rating

1A

Tripping Characteristics

Type C

Rated AC Voltage

266V

Rated DC Voltage

250V

Breaking Capacity at Maximum Voltage Rating

10 kA

Range

System Pro M Compact

Series

S200 MTUC

Circuit Breaker Type

MCB

Length

88mm

Width

17.5mm

Mounting Style

DIN Rail Mount

Depth

69mm

Model Number

S201MT-C1UC

Reset Actuator Type

Toggle Switch

Terminal Contact Type

Screw

COO (Country of Origin):
DE

ABB S200 MTUC Series MCB, 1 Pole, 1A Current Rating - 2CDS271065R0014 S201MT-C1U


This miniature circuit breaker provides essential protection for electrical installations, especially in automation and control systems. With a rating of 1A, it is built for dependable performance across a range of electrical environments.

Features & Benefits


• Compact design allows for straightforward installation on DIN rail
• Type C tripping characteristic improves safety with inductive loads
• Rated short-circuit capacity of 10kA ensures robust protection
• Operating temperature range of -25°C to +55°C offers versatility
• Energy limiting class II reduces arc energy to enhance safety
• Screw terminals ensure secure and dependable connections

Applications


• Protects circuits in industrial control panels
• Suitable for residential and commercial electrical systems
• Ideal for motor protection and automation
• Used in electrical distribution boards to promote safety

How can I ensure compatibility with existing electrical systems?


It is important to verify the rated current and operational voltage with your existing installations prior to integration.

What step should I take for installation on a mounting rail?


Align the device with the DIN rail and push down until it clicks securely into place.

How often should the device be inspected for maintenance?


Regular inspections every six months are advisable to maintain proper operation and safety.

Can it be used in humid environments?


Yes, as long as ambient temperature and humidity levels stay within the specified operating conditions.

What should be done if a tripping occurs?


Investigate the cause of the overload or fault and reset the breaker only after the issue has been resolved to ensure safety.

관련된 링크들