Schneider Electric TeSys TeSys Miniature Circuit Breaker, 3-Pole, 320 A, 690 V ac AC, 36 kA Breaking Capacity

Subtotal (1 unit)*

₩2,519,989.60

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 5월 01일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩2,519,989.60

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
188-4752
제조사 부품 번호:
GV6P320F
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Product Type

Miniature Circuit Breaker

Number of Poles

3

Current Rating

320 A

Rated AC Voltage

690 V ac

Breaking Capacity

36kA

Mount Type

DIN Rail

Range

TeSys

Series

TeSys

IP Rating

IP20

Depth

255mm

Height

140mm

Width

255 mm

Standards/Approvals

CSA C22.2 No. 60947-4-1, EN IEC 60947-4-1, UL 60947-4-1, EN IEC 60947-1, EN IEC 60947-2

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Handle

Break Time

Instantaneous

제외

Schneider Electric TeSys GV5 and GV6 TeSys Giga MCB Motor Circuit Breakers.


The TeSys range of MCB Motor circuit breakers GV5 and GV6, designed to protect motors from overloads, short circuits, phase unbalance and phase loss.

TeSys GV5 and GV6 are now part of the TeSys Giga range of circuit breakers. TeSys GV5 and GV6 are coordinated with TeSys Giga contactors. The TeSys Giga motor circuit breakers will give you even better protection and are perfect for demanding applications, combining advanced electronics and up to date electromechanical technology. Easily installed thanks to universal Screw fixing plus the automatic compensation for temperature changes and international standards compliance this motor circuit breaker provides excellent protection.

TeSys Giga GV5 and GV 6 MCB Features.


  • Choice of 4 x current ratings – 150 A, 220 A, 320 A, 500 A.

  • Advanced Micrologic trip unit (overload, short circuit, Phase loss and unbalance protection).

  • Adjustable overload protection (Ir): 50 to 100% x In, includes trip class selection (Class 5, 10 or 20)

  • Adjustable Short-time protection threshold (Isd): 5 to 13 x In with fixed time delay

  • Short-Circuit instantaneous protection (Ii): 15 x In (max rating of the trip unit)

  • Front LED indications: Green LED for pre-alarm before event of fault and Red LED for motor operation

  • Suitable for isolation, as per IEC standards

  • Control by direct rotary handle as standard, by door-mounted extended rotary handle as option

  • Connections: busbars/ cables with lugs

  • Compliance with standards: EN/IEC 60947-1; IEC 60947-2; IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1

  • Optional Thermal Fault module (SDTAM) to indicate over-load and to open contactor (before breaker tripping) in event of over-load or phase un-balance

  • Type 1 or type 2 short-circuit co-ordination, when combined with TeSys Giga contactors.

  • TeSys Giga GV5 and GV 6 MCB Applications.


  • Various application covering industry, infrastructure, and building, including:

  • Commercial property, construction, hospitals, facilities.

  • Utilities, Oil, Gas, Energy, Water, Waste-water treatment.

  • Machinery, materials handling, mining, metals, processing plants.

  • GV6P320F TeSys GV6P Motor Protection MCB Circuit Breaker.


  • Category A to IEC 60947-2.

  • Direct rotary handle / knob / switch.

  • Isolation to EN/IEC 60947-2.

  • Breaking capacity code F 36 kA.

  • Overvoltage category III.

  • Micrologic 2.3 M Trip unit (320 A, Electronic, 4800 A trip current).

  • Overload Class 5 conforming to IEC 60947-4-1, Class 10 conforming to IEC 60947-4-1, Class 20 conforming to IEC 60947-4-1.

  • Phase failure to IEC 60947-4-1.

  • Signals LED ready / LED 95% lth.

  • Mounts horizontally and vertically by screws.

  • Weight 6.5 kg.

  • Operating temperature -25°C to 70°C.

  • Colour of MCB is RAL 7016 – Anthracite.

  • Overload protection.

  • Short-circuit protection.

  • Instantaneous short-circuit protection.

  • Phase unbalance.

  • Phase loss.

  • Breaking Capacity.


  • 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2.

  • 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2.

  • 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2.
  • ;Durability.;
  • Mechanical 15,000 cycles.

  • Electrical 6,000 cycles or AC-3 at 400/415 V In.
  • ;Protection.;
  • IP40 IEC 60529.

  • IK07 IEC 62262.

  • Fire resistant to 960 °C conforming to IEC 60695-2-1.

  • Vibration resistant to IEC 60068-2-6.

  • Approvals

    IECEE CB Scheme

    Standards

    EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1.