ABB S300P Miniature Circuit Breaker, 2-Pole, 16A, Type B, 415V ac AC, 125 V dc DC, 100 kA Breaking Capacity

Subtotal (1 unit)*

₩388,960.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 3 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩388,960.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
200-909
제조사 부품 번호:
2CDS382001R0165
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

2

Current Rating

16A

Tripping Characteristics

Type B

Rated AC Voltage

415V ac

Rated DC Voltage

125V dc

Breaking Capacity

100kA

Mount Type

DIN Rail

Series

S300P

Terminal Type

Screw

IP Rating

IP20, IP40

Depth

69mm

Height

88mm

Width

35mm

Standards/Approvals

UL 489 CSA .. . 5 IECEN 60947

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB S300P Series Miniature Circuit Breaker, 16A Current, 125V dc Rated Voltage - 2CDS382001R0165


This miniature circuit breaker provides overcurrent protection for low-voltage electrical systems and is designed for rail-mounted installations. It operates across AC and DC supplies and employs a toggle reset for manual reclosing. The device meets recognised international standards and is intended for use where Compact protection and straightforward wiring are required.

Features and Benefits:


• 25kA breaking capacity delivers high fault interruption capability
• Type B tripping offers sensitivity to low-level fault currents
• 2-pole configuration ensures simultaneous disconnection of both conductors
• Screw terminals provide secure conductor retention under vibration
• DIN rail mount enables Rapid panel installation and removal

Applications


• Suitable for control panels in light industrial installations
• Ideal for DC-fed circuits requiring 125V protection
• Used with three-phase distribution up to 415V AC systems
• Can be used for protection of small motor and lighting circuits
• Suitable for modular distribution boards in commercial buildings

What physical mounting method does it require?


It clips onto a standard DIN rail for straightforward panel integration.

How is the breaker manually operated after a trip?


A toggle-style reset actuator allows manual reset without tools.

What ingress protection does the enclosure provide?


It typically offers IP20 protection and IP40 in higher-access-control configurations.

Which Terminal connection type is provided for conductors?


Screw-type terminals are used for conductor termination and clamping.

What tripping characteristic controls its instantaneous behaviour?


A Type B characteristic determines instantaneous trip thresholds for low-level faults.