ABB S300P Miniature Circuit Breaker, 2-Pole, 50A, Type Z, 415V ac AC, 125 V dc DC, 25 kA Breaking Capacity

Subtotal (1 unit)*

₩709,320.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2027년 1월 04일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩709,320.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
200-302
제조사 부품 번호:
2CDS382001R0578
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Number of Poles

2

Product Type

Miniature Circuit Breaker

Current Rating

50A

Tripping Characteristics

Type Z

Rated AC Voltage

415V ac

Rated DC Voltage

125V dc

Breaking Capacity

25kA

Mount Type

DIN Rail

Series

S300P

Terminal Type

Screw

IP Rating

IP20, IP40

Width

35mm

Standards/Approvals

IEC/EN 60947-2 IEC/EN 60898-1 UL 1077 CSA 22.2. No.235 GB/T 14048.2 GB/T 10963.1

Height

88mm

Depth

69mm

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB S300P Series Miniature Circuit Breaker, 50A Current, 125V dc Rated Voltage - 2CDS382001R0578


This miniature circuit breaker provides overcurrent protection for low-voltage installations and is intended for mounting on a DIN rail in control panels and distribution boards. It is designed to interrupt fault currents in both AC and DC systems, offering a Compact protection device with a toggle reset for straightforward reset operations in electrical distribution environments.

Features and Benefits:


• 25kA breaking capacity provides secure fault interruption
• 415V AC rating supports three-phase and single-phase AC supplies
• 125V DC rating enables use in DC‑powered circuits
• Type Z tripping characteristic offers protection for sensitive loads
• Screw Terminal connection ensures robust conductor retention

Applications


• Suitable for protection of panel-mounted distribution circuits
• Ideal for DC battery and solar sub-circuit protection
• Used with industrial control equipment on DIN rail
• Can be used for residential dual‑pole branch circuits
• Suitable for retrofit installations requiring Compact protection

What mounting method is required for installation?


It mounts directly onto a DIN rail using standard clip engagement.

Which enclosure protection levels are available?


It is provided with IP20 and IP40 ratings for differing installation exposures.

What pole configuration does it offer?


It is supplied as a two‑pole device for simultaneous disconnection.

What Terminal type is used for conductor connection?


Terminals are screw type to secure incoming and outgoing conductors.

관련된 링크들