ABB S801S MCB, 1P, 125A, UC-B, 250V DC, 50 kA Breaking Capacity

Subtotal (1 unit)*

₩612,836.76

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 3월 04일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩612,836.76

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
140-611
제조사 부품 번호:
2CCS861001R1845
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Number of Poles

1

Current Rating

125A

Tripping Characteristics

UC-B

Rated DC Voltage

250V

Breaking Capacity at Maximum Voltage Rating

50 kA

Series

S801S

Circuit Breaker Type

MCB

Length

82.5mm

Width

27mm

Mounting Style

DIN Rail

Depth

82.5mm

Model Number

S801S-UCB125

Terminal Contact Type

Screw

COO (Country of Origin):
CH

ABB S801S Series MCB, 1 Pole, 125A Current Rating - 2CCS861001R1845


This MCB is designed to provide high performance in electrical systems. With a compact design measuring 27mm in width and 82.5mm in length, it is well-suited for mounting on DIN rails. This single pole circuit breaker is rated at 125A and features UC-B tripping characteristics, ensuring reliable operation in various applications.

Features & Benefits


• 50 kA breaking capacity to manage high fault levels
• Rated DC voltage of 250V for enhanced versatility
• Designed for easy connection with screw terminals
• Operating range of -25 to +60 °C for diverse environments
• Energy limiting class ensures minimal downstream damage
• IP20 protection degree suitable for indoor installations

Applications


• Used for protecting circuits in solar power systems
• Fits into industrial automation setups for safety purposes
• Ideal for requiring reliable power distribution
• Utilised in commercial electrical systems for protective measures

What environmental conditions can this device withstand?


It operates effectively between -25 °C and +60 °C, accommodating various climates and operational demands.

What type of connections does this circuit breaker support?


It supports screw terminal connections, suitable for flexible cables from 0 to 50 mm² and rigid cables up to 70 mm².

How does the breaking capacity influence the system’s safety?


The 50 kA breaking capacity allows it to interrupt high fault currents, thereby reducing the risk of damage to the main electrical system and improving safety.

What does the UC-B tripping characteristic signify for usage?


UC-B characteristics enable the breaker to respond to overloads and short circuits, ensuring quick disconnection of faulty circuits.

Can this device be integrated into existing installations?


Yes, it is compatible with standard DIN rail systems, making installation straightforward in existing electrical setups.