RS PRO 686 Series Surface Mounted Momentary Air Switch

Subtotal (1 unit)*

₩35,160.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 8월 24일 부터 4 개 단위 배송
  • 추가로 2026년 8월 31일 부터 10 개 단위 배송
  • 추가로 2026년 10월 05일 부터 10 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩35,160.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
316-951
제조업체:
RS PRO
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

RS PRO

Sub Type

Momentary

Product Type

Air Switch

Mount Type

Surface

Contact Configuration

1 NO/1 NC

Series

686

For Use With

3 mm I/D Tubing, Battery Charging Rooms, Garages or Wherever Explosive Gases, Laboratories, Vapours or Powders May Exist

Standards/Approvals

UL

COO (Country of Origin):
GB

Air Operated Switches, 2-Pole Element, Surface Mount


The momentary action switch unit incorporates two SPDT microswitch contacts, one switch operating before the other, i.e. an increase in applied pressure on the actuator is required to operate the second switch

The alternate action switch unit incorporates two SPDT microswitch contacts, acting simultaneously

Each switch is rated at 15 A, 250 V ac. Mounted by four No. 4 self-tapping screws

Operating pressure 1.2 psi

Maximum pressure 15 psi

Actuators, Switch Elements, Tubing & Accessories


The air operated switch system offers enhanced safety in hazardous areas by allowing remote operation of electrical circuits.

The actuator is a bellows which, when compressed moves air down the air tubing to the switch element. This compressed air then expands a bellows in the switch, which operates the electrical contacts.

When used in wet environments or where electrical switching would be dangerous due to arcing, the switch and all electrical wiring can be located outside the hazardous area giving the operator total electrical isolation for the equipment.

Such applications include: Battery charging rooms, laboratories, garages, or wherever explosive gases, vapours or powders may exist.

When assembled the air switch and actuator form a sealed system, therefore temperature variation will cause pressure changes, which can in extreme cases affect the performance of the switch. To prevent this the total volume of the system must be kept below a critical value for a given temperature range and, to this end, a maximum length of air tubing (and hence volume) can be given for any combination of switch and actuator.

The additional data tables give these lengths in metres; for moderate and extreme temperatures.

Note

The mounting screw length must not exceed 6mm otherwise the bellows may be punctured.