Telemecanique Sensors OsiSense XC Series Roller Plunger Limit Switch, 1 NO/1 NC, IP67, IP66, Plastic Housing, 240V ac,

Subtotal (1 unit)*

₩200,120.00

Add to Basket
수량 선택 또는 입력
제한된 재고
  • 6 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩200,120.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
814-7829
제조사 부품 번호:
XCKP2121M12
제조업체:
Telemecanique Sensors
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Telemecanique Sensors

Actuator Type

Roller Plunger

Product Type

Limit Switch

IP Rating

IP67, IP66

Contact Configuration

1 NO/1 NC

Housing Material

Plastic

Contact Type

Snap Action

Switching Current

3A

Terminal Type

Screw

Series

OsiSense XC

Minimum Operating Temperature

-25°C

Switching DC Voltage

250V dc

Switching AC Voltage

240V ac

Maximum Operating Temperature

70°C

Depth

30mm

Length

65mm

Width

31mm

Standards/Approvals

CE, UL, RoHS, IEC, EN, CSA

Hazardous Area Certification

No

Operating Force

0.1Nm

Mechanical Life

1000000Operations

Mounting Orientation

Front

Conduit Entry

M12

제외

COO (Country of Origin):
ID

Telemecanique Sensors OsiSense XC Series Limit Switch, IP67, Roller Plunger Actuator Type - XCKP2121M12


This limit switch provides precision actuation for industrial control and safety applications. It uses a roller plunger actuator housed in a plastic enclosure and is designed for front mounting in machinery where a compact, sealed switching device is required. The unit switches AC and DC circuits and includes a screw Terminal Interface for straightforward wiring.

Features and Benefits:


• Snap action contacts deliver quick, repeatable state changes
• 1NO/1NC configuration enables simple changeover control
• Rated for 250Vdc and 240Vac switching for versatile circuits
• Switching current 3A supports low-to-moderate power loads
• M12 conduit entry simplifies cable routing and sealing
• Operating torque 0.1Nm allows sensitive actuation response

Applications


• Suitable for conveyor end-of-travel detection
• Ideal for door position sensing in enclosures
• Used with pick-and-place equipment for limit detection
• Can be used for safety interlocks on access panels
• Used for position feedback in packaging machinery

What environmental protection does it provide?


It is available with IP67 and IP66 ingress protection ratings suitable for dust and temporary or high-pressure water exposure.

What temperature range can it operate within?


It functions between -25°C and 70°C for typical industrial ambient conditions.

How long will the switching mechanism last under normal use?


The mechanical life is rated to 1,000,000 operations indicating extended service before mechanical wear limits.

What connection method is provided for field wiring?


Electrical connections are MADE via screw terminals and a single M12 conduit entry for cable ingress.

관련된 링크들