SICK C2C Series Light Curtain Receiver, 14 mm Resolution

Subtotal (1 unit)*

₩815,000.00

Add to Basket
수량 선택 또는 입력
제한된 재고
  • 1 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩815,000.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9391
제조사 부품 번호:
C2C-EA03010A10000
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Light Curtain

Series

C2C

Beam Resolution

14mm

Component Type

Receiver

Safety Type

2

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

300mm

Maximum Supply Voltage

24V dc

Maximum Scanning Distance

10m

Maximum Response Time

11ms

Width

34mm

Terminal Type

M12 Connector

COO (Country of Origin):
DE

SICK C2C Series Light Curtain, 300mm Protective Height, 10m Scanning Distance - C2C-EA03010A10000


This light curtain is a receiver device designed for safeguarding access points in normal industrial environments. It provides a protective optical field to detect intrusions and integrates with control systems via a plug-in M12 connector. The unit operates from a 24 VDC supply and is suitable for use where monitored stop and machine guarding are required. It is built to withstand industrial ambient conditions including a wide temperature range and ingress protection.

Features and Benefits:


• 14mm beam resolution enables detection of small objects
• 11 MS response time supports Rapid machine stop functionality
• 10m scanning distance allows long-range protection zones
• 2 PNP OSSD outputs provide cross-circuit monitored switching
• IP65/IP67 enclosure rating ensures protected outdoor use

Applications


• Suitable for machine guarding on production lines
• Can be used for access protection at loading bays
• Ideal for integration with safety relays and controls
• Used with automated equipment requiring optical synchronisation
• Suitable for environments demanding Compact sensor width

What type of synchronisation does it use?


It uses optical synchronisation between sender and receiver.

How are the output circuits configured?


Two PNP semiconductor OSSDs are short‑circuit protected and cross‑circuit monitored.

What environmental limits apply during operation?


Operating temperature range is -30°C to +55°C with 15%-95% non‑condensing humidity.

How is the device electrically connected to the control system?


System connection is via a 5‑pin M12 plug with a 150mm cable length.

What safety classifications does it meet?


It is Type 2 with SIL1, Category 2 and PL c performance levels.