SICK C2C Series Light Curtain Sender, 14 mm Resolution

Subtotal (1 unit)*

₩1,103,460.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 10일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩1,103,460.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-0959
제조사 부품 번호:
C2C-SA07510A10000
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Light Curtain

Series

C2C

Beam Resolution

14mm

Component Type

Sender

Safety Type

2

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

750mm

Maximum Supply Voltage

24V

Maximum Scanning Distance

10m

Height

32.8mm

Length

150mm

Width

34mm

Terminal Type

M12 Male Connector

COO (Country of Origin):
DE

SICK C2C Series Light Curtain, 750mm Protective Height, 14mm Beam Resolution - C2C-SA07510A10000


This Compact industrial safety device protects access points by detecting interruptions in an infrared beam array and is intended for use in standard manufacturing environments. Designed as a sender unit for a two-part protective system, it operates with optical synchronisation and is suitable where a 10m range between sender and receiver is required. The enclosure provides resistance to dust and moisture and the unit uses a 5‑pin M12 plug for system connection.

Features and Benefits:


• 14mm beam resolution for fine object detection and precise safeguarding
• 10m scanning distance enabling long-range guarding across gaps
• Type 2 safety classification supporting PLc and SIL1 risk levels
• Optical synchronisation preventing mutual interference in multi-beam setups
• Aluminium profile housing for robust, low-mass installation

Applications


• Suitable for machine guarding on automated production lines
• Used with safety relays for controlled restart interlock functions
• Ideal for perimeter protection where 10m range is needed
• Can be used for access protection on material handling equipment
• Used with compatible receivers to form a full protective field

What electrical connection does it require?


It connects via a 5‑pin M12 male connector and operates from 24V DC within 19.2V to 28.8V.

How does it behave when a fault occurs?


A fault forces at least one OSSD into the OFF state, maintaining the safe condition.

What environmental conditions can it withstand?


It is rated to IP65 and IP67 and functions between -30°C and +55°C.

How long is its expected mission time?


The device has a TM of 20 years as specified for safety performance.