SICK C4C Series Light Curtain Sender, 30 mm Resolution

Subtotal (1 unit)*

₩3,253,160.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 10일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩3,253,160.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
284-9202
제조사 부품 번호:
C4C-SB09030A10000
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Light Curtain

Series

C4C

Beam Resolution

30mm

Component Type

Sender

Safety Type

Type 4

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

900mm

Maximum Supply Voltage

24V dc

Maximum Scanning Distance

12.5m

Height

1.069m

Terminal Type

Flying Lead

COO (Country of Origin):
DE

SICK C4C Series Light Curtain, 900mm Protective Height, 12.5m Scanning Range - C4C-SB09030A10000


This light curtain is a sender module designed to provide a monitored protective field for machinery and production lines where hygiene-rated housings are required. It operates as part of a two-piece safety system to detect interruptions in the protective field and switch safety outputs accordingly, using near-infrared light at 850nm and optical synchronisation for reliable detection over extended distances.

Features and Benefits:


• Type 4 safety classification delivering high-integrity protection
• 30mm beam resolution providing fine object detection capability
• 24V DC supply operation enabling standard industrial integration
• 12.5m maximum scanning distance supporting long-range layouts
• IP69K housing with stainless end caps for hygiene environments

Applications


• Suitable for safeguarding conveyor infeed and discharge zones
• Ideal for integration with relay-based safety circuits
• Used with processing equipment requiring washdown protection
• Can be used for perimeter protection on automated cells
• Suitable for installations needing optical synchronisation between units

What supply wiring is provided with the unit?


A 15m PUR halogen-free connecting cable with five flying leads is supplied.

How does the unit indicate alignment and operation status?


Built-in LEDs show operating and alignment conditions for commissioning.

What are the environmental limits for operation?


It functions between -30°C and +55°C with 15%-95% non‑condensing humidity.

How does the sender behave on fault detection?


At least one OSSD is forced to the OFF state to achieve a safe condition.

Which approvals cover electrical and safety standards?


It holds multiple approvals including EC-Type-Examination, GB/T, IEC, OSHA, RoHS and cULus.