Chauvin Arnoux CA 6550 Insulation Tester, 40 V Min, 10000 V Max CAT IV
- RS 제품 번호:
- 237-2905
- 제조사 부품 번호:
- P01139715
- 제조업체:
- Chauvin Arnoux
Subtotal (1 unit)*
₩14,618,038.50
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 + | ₩14,618,038.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 237-2905
- 제조사 부품 번호:
- P01139715
- 제조업체:
- Chauvin Arnoux
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Chauvin Arnoux | |
| Product Type | Insulation Tester | |
| Model Number | CA 6550 | |
| Tester Type | Insulation Tester | |
| Maximum Test Voltage | 10000V | |
| Minimum Test Voltage | 40V | |
| Display Type | LCD | |
| Power Source | Battery | |
| Battery Life | 2h | |
| Safety Category Level | CAT IV | |
| Safety Category Voltage | 1000V | |
| Length | 340mm | |
| Standards/Approvals | CE | |
| Width | 300mm | |
| Height | 200mm | |
| Weight | 6.2kg | |
| 모두 선택 | ||
|---|---|---|
브랜드 Chauvin Arnoux | ||
Product Type Insulation Tester | ||
Model Number CA 6550 | ||
Tester Type Insulation Tester | ||
Maximum Test Voltage 10000V | ||
Minimum Test Voltage 40V | ||
Display Type LCD | ||
Power Source Battery | ||
Battery Life 2h | ||
Safety Category Level CAT IV | ||
Safety Category Voltage 1000V | ||
Length 340mm | ||
Standards/Approvals CE | ||
Width 300mm | ||
Height 200mm | ||
Weight 6.2kg | ||
- COO (Country of Origin):
- FR
The Chauvin Arnoux CA 6550 and CA 6555 megohmmeter are tools of excellence to perform insulation checks with safety and precision. Their use on equipment and rotating machines, operating at 12 kV and above, complies with recommended practices. The multiple test modes allow both qualitatively qualifying non-control isolations. Also it investigate the problems on samples of insulation aging for the purpose of preventive maintenance.
Measuring range from 10 kΩ to 30 TΩ
Fixed or programmable test voltage from 40 V to 10/15 kV
5 mA load current
Real-time graphic display R (t) + u (t), i (t), i (u)
DAR / PI / DD / ΔR ratios (ppm / V)
Ramp and voltage step modes with burning mode,
"Early break" and "I-limit"
3 filters to optimize measurement stability
Calculation of R at a reference temperature
Memory capacity 80,000 measurements and Real time clock
Report generation via DataView software
관련된 링크들
- Chauvin Arnoux CA 6555 Insulation Tester, 40 V Min, 15000 V Max CAT IV
- Chauvin Arnoux P01295465 Insulation Tester HV Test Lead Set Lead, For Use With CA 6555, CA 6550
- Chauvin Arnoux P01295524 Insulation Tester HV Test Lead Set Lead, For Use With CA 6555, CA 6550
- Chauvin Arnoux P01295520 Insulation Tester HV Test Lead Set Lead, For Use With CA 6555, CA 6550
- Chauvin Arnoux P01295521 Insulation Tester HV Test Lead Set Lead, For Use With CA 6555, CA 6550
- Chauvin Arnoux P01295522 Insulation Tester HV Test Lead Set Lead, For Use With CA 6555, CA 6550
- Chauvin Arnoux Insulation & Continuity Tester, 10 V Min, 100 V Max CAT IV
- Chauvin Arnoux Insulation & Continuity Tester, 10 V Min, 500 V Max CAT IV