Fluke 62 MAX Infrared Thermometer, -30 °C Min, +500 °C Max, ± 1.5 °C Accuracy, Fahrenheit, °C, F Measurements

Subtotal (1 unit)*

₩414,320.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 11 개 단위 배송 준비 완료
  • 추가로 다른 지역에서 118 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩414,320.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
760-0385
Distrelec 제품 번호:
176-67-053
제조사 부품 번호:
FLUKE-62 MAX
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Maximum Temperature Measurement

+500°C

Product Type

Infrared Thermometer

Battery Type

AA

Temperature Scale

Fahrenheit, °C, F

Accuracy

± 1.5 °C

Minimum Temperature Measurement

-30°C

Distance to Spot Ratio

10:1

Emissivity

Adjustable, 0.1 to 1

Model Number

62 MAX

Resolution

0.1 °C

Response Time

500ms

Power Source

Battery

Battery Life

10h

Width

85mm

Hazardous Area Certification

No

Standards/Approvals

IEC 61010-1

Length

175mm

Height

75mm

Weight

255g

제외

Fluke Infrared Thermometer, +500°C Maximum Temperature, 10:1 Distance to Spot Ratio - FLUKE 62 MAX


This infrared thermometer is a Compact non-contact instrument designed to measure surface temperatures quickly in industrial environments. It provides Rapid spot readings across a wide span for diagnostics and maintenance tasks while withstanding rough handling and ingress from dust and water.

Features & Benefits


• 10:1 D:S optical ratio enables safer distance measurements
• ±1.5°C accuracy delivers consistent measurement confidence
• -30 to 500°C range covers most industrial surfaces
• Adjustable emissivity 0.10–1.00 adapts to material types
• 0.1°C resolution reveals small temperature differences
• Fast 500 MS response reduces wait time for readings

**Applications**


• Suitable for inspecting motor and gearbox bearings
• Ideal for checking panel and distribution board temperatures
• Used for verifying PCB and component thermal behaviour
• Can be used for preventive maintenance of HVAC systems
• Suitable for on-site conveyor and belt monitoring

What power source does it use and how long does it run?


It runs from a single AA battery and typically operates for about 10 h with laser and backlight on.

How rugged is the instrument for field use?


The housing survives drops from 3M and carries an IP54 ingress rating for protection against dust and splashing water.

What standards does it meet for laboratory or site acceptance?


It complies with IEC 61010-1 safety requirements for electrical measurement instruments.

How does it indicate measurements outside set limits?


It provides Hi and Lo alarms to flag temperatures beyond preset thresholds.

Approvals

FDA and EN 60825-1 Class II

Standards

EN/IEC 61010-1: 2001