SICK Bar Code Reader 735 mm Ethernet 5 W 30V

Subtotal (1 unit)*

₩4,392,531.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 2 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩4,392,531.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
213-3745
제조사 부품 번호:
CLV630-0120
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Bar Code Reader

Device Type

Barcode Reader

Optical Technology

Laser

Reading Distance

735mm

Interface Type

Ethernet

Maximum DC Voltage

30V dc

Terminal Type

Cable

Maximum Supply Voltage

30V

Minimum Operating Temperature

0°C

Power Consumption

5W

Maximum Operating Temperature

40°C

Standards/Approvals

EN 61000-6-3 (2001-10)/EN 61000-6-2:2005, EN 60068-2-6 (1995)

Series

CLV63x

Depth

38mm

Length

61mm

Width

96mm

SICK CLV63x Series Bar Code Reader, 735mm Reading Distance, 5W Power Consumption - CLV630-0120


This barcode reader is a Compact laser-based imaging device designed for high-speed code capture in industrial settings. It operates in automated production and inspection environments, providing wired network connectivity for integration into factory systems. The unit is intended for continuous operation within controlled ambient temperatures and connects via a fixed cable for power and data transmission.

Features and Benefits:


• Laser scanning delivers long-range reading at 735mm
• Ethernet Interface enables direct network integration
• Low electrical draw reduces power budget at 5 W
• Accepts supply up to 30V for flexible installation
• Operates reliably between 0 °C and 40 °C for factory use

Applications


• Suitable for conveyor-based code verification in automation lines
• Ideal for machine Vision stations requiring long read range
• Used for warehouse sorting where Ethernet connectivity is required
• Can be used for traceability on assembly lines with continuous operation

What electromagnetic compatibility standards does it meet?


It conforms to immunity and emissions standards covering residential and industrial environments as defined by the relevant EN 61000-6 series requirements.

How is the device wired into a control system?


A permanently fitted cable provides the electrical and data connection designed for integration with Ethernet-based industrial networks.

What environmental testing supports mechanical robustness?


The unit has been subjected to standardised vibration testing in accordance with established EN 60068-2-6 procedures.

What are the physical envelope considerations for mounting?


The reader occupies a Compact footprint measuring 96mm x 61mm x 38mm, allowing installation in constrained enclosures.

관련된 링크들