Staubli FlexiVolt Series Red 0.50 mm² Hook Up Wire, 20 AWG, 129 x 70 μm, 70 μm core strands, 100 m, Polyvinyl Chloride

대량 구매 할인 받기

25개 더 담고 2% 할인 받기

View bulk pricing options

Subtotal (1 reel of 100 metres)*

₩152,560.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 11 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

릴당
릴당
미터당*
절감
1 - 24₩152,560.00₩1,526.00-
25 +₩148,760.00₩1,488.002%

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-7836
제조업체:
Staubli
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Staubli

Product Type

Hook Up Wire

Cross Sectional Area

0.50mm²

Jacket Colour

Red

American Wire Gauge

20AWG

Core Strands

129 x 70 μm

Cable Length

100m

Outside Diameter

2.1mm

Voltage

500V

Maximum Operating Temperature

70°C

Conductor Material

Copper

Minimum Operating Temperature

-10°C

Standards/Approvals

RoHS Compliant

Sub Type

Unscreened

Cable Type

Stranded

Jacket Material

Polyvinyl Chloride

Fire Behaviour

UV-resistant

Series

FlexiVolt

Number of Strands

129

Size of Strands

70μm

COO (Country of Origin):
DE

Staubli FlexiVolt Series Hook Up Wire, 20 AWG Conductor Size, 0.50mm² Cross Sectional Area - 60.7004-999-22


This hook-up wire is intended for flexible interconnections in electronic assemblies and wiring harnesses. It comprises a stranded copper conductor insulated with red PVC, designed to perform across a range of temperatures and provide resistance to ultraviolet exposure. The product is supplied on a 100 m reel for continuous runs and routine installation tasks.

Features and Benefits:


• 129 strands of 0.07 mm provide enhanced flexing capability
• 500 V rating supports medium-voltage internal wiring applications
• Temperature range -10 °C to 70 °C enables varied operating environments
• UV‑resistant PVC jacket resists sunlight degradation on exposed runs
• RoHS compliance reduces hazardous substance content in installations

Applications


• Suitable for wiring-harness assemblies in control panels
• Ideal for flexible interconnects in consumer electronics
• Used with Terminal blocks and connector-pin terminations
• Can be used for repair and prototype wiring on test rigs
• Appropriate for signal and low-power power-distribution tasks

What conductor construction aids repeated bending?


The conductor is MADE from 129 finely stranded copper wires sized 0.07 mm which increases flexibility and fatigue resistance.

How is the insulation specified for outdoor-exposed cabling?


The outer sheath is polyvinyl chloride formulated to be UV‑resistant, reducing surface weathering when deployed in sunlight.

What reel length is supplied for continuous laying?


The cable is provided on a 100 m length suitable for extended internal runs and harness fabrication.

Which electrical parameters define safe voltage use?


The insulation system is rated for 500 V which determines maximum working voltage for internal wiring.

How does the cross-sectional area relate to current capacity?


The conductor area is 0.50 mm², which guides current-carrying considerations for low-power and signal circuits.

관련된 링크들