Honeywell AWM40000 Series Amplified Airflow Sensor for Dry Gas, 1000cm³/s Max

대량 구매 할인 기용 가능
View bulk pricing options

Subtotal (1 unit)*

₩440,973.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 100 개 단위 배송 준비 완료
  • 추가로 2026년 6월 26일 부터 2 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

수량
한팩당
1 - 4₩440,973.00
5 +₩427,732.50

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
623-7927
Distrelec 제품 번호:
303-44-919
제조사 부품 번호:
AWM43300V
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Media Monitored

Dry Gas

Product Type

Airflow Sensor

Device Type

Amplified

Maximum Flow Rate

1000cm³/s

Housing Material

Plastic

Maximum Pressure

150psi

Maximum Supply Voltage

15V dc

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

85°C

Standards/Approvals

No

Series

AWM40000

비준수

COO (Country of Origin):
CN

Honeywell Amplified Airflow Sensor, 1000sccm, 8 to 15V DC - AWM4000 Series - AWM43300V


Measure the flow rate of Air in your system with this Airflow sensor from Honeywell. It's commonly used with medical equipment such as respirators and ventilators. For versatility, the device accurately senses flow rates between 0.1 and 1000sccm. Its plastic housing material makes it Durable and resistant to wear for long-lasting performance. For ease of installation, you can mount this sensor to a PCB.

Features & Benefits


• Fast typical response time of 1ms for almost immediate airflow readings

• Supply voltage range of 8 to 15V DC for use in low-voltage applications

Applications


• Heating and ventilation systems

• Robotics

• Automated assembly lines

• Pharmaceutical industry

Can I use this sensor in extreme temperatures?


Yes, thanks to its broad operating temperature range of -25°C to +85°C, this sensor is suitable for use in demanding environments.

Amplified Airflow Sensor AWM40000 Series


The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.;When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.

These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.;The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.

The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.

Features and Benefits


• Manifold mount/o-ring sealed;• Ceramic flow tube (non-outgassing), 0 to 1000 sccm;• High common mode pressure (150 psi ceramic flow tube only);• Operating temperature up to 125°C;• High stability at null and full scale

Product Application Information


• Damper control for heating, ventilation, and Air conditioning systems;• Gas analysers;• Low vacuum control;• Process control;• Medical respirators and ventilators;• Oxygen concentrators;• Leak detection equipment;• Vent hoods;• Anaesthesia control;• Gas metering;• Gas chromatography

관련된 링크들