StarTech.com NLBK Cat6a Ethernet Cable, 5 m, Shielded Screened, Black Low Smoke Zero Halogen

Subtotal (1 unit)*

₩43,460.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 11 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩43,460.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
256-6958
제조사 부품 번호:
NLBK-5M-CAT6A-PATCH
제조업체:
StarTech.com
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

StarTech.com

Product Type

Ethernet Cable

Series

NLBK

LAN Category

Cat6a

Cable Length

5m

Terminated/Unterminated

Terminated

Shield Type

Shielded

Screened/Unscreened

Screened

Conductor Type

Stranded

Jacket Material

Low Smoke Zero Halogen

Jacket Colour

Black

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+50°C

Standards/Approvals

CE, RoHS Compliant

Fire Behaviour

Low Smoke Zero Halogen (LSZH)

Number of Cores

4

Outside Diameter

5.70mm

Conductor Material

Stranded Copper

Size of Strands

27AWG

StarTech NLBK Series Ethernet Cable, 5m Cable Length, Black - NLBK-5M-CAT6A-PATCH


This Ethernet cable provides shielded network connectivity for 10GBASE-T installations and PoE++ deployments. It is intended for use where reduced emissions and low hazardous fume output are required, allowing safe routing in enclosed or poorly ventilated spaces. The cable combines screened pair shielding with stranded conductors to support high-frequency signal transmission and powered devices over a single link.

Features and Benefits:


• 10Gbps data rate improves high-throughput network performance
• 500MHz bandwidth reduces signal loss at high frequencies
• 27AWG stranded copper lowers resistance and enhances conductivity
• S/FTP screening limits electromagnetic interference for stable links
• LSZH jacket emits low toxic fumes for safer enclosed installations

Applications


• Suitable for connecting 10G switches in data centres
• Used with PoE++ access points and IP cameras
• Ideal for 10G NAS and SFP module interconnects
• Can be used in trains and aircraft where LSZH is required

What conductor configuration does it use?


It uses four pairs of stranded copper conductors with individual pair foil shielding and an overall braided shield.

What PoE power level can it support?


It is rated to carry up to 100W for IEEE 802.3bt Type 4 PoE++ applications.

What testing verifies its performance?


Each cable is individually tested using industry cable analysers and ETL verification for Cat6a compliance.

Which environmental temperatures can it operate within?


The cable operates between 0°C and +50°C.

관련된 링크들