Siemens 6XV Cat6a Ethernet Cable, 10 m, Shielded, Green

Subtotal (1 unit)*

₩273,020.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 7 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩273,020.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
252-3666
제조사 부품 번호:
6XV18785BN10
제조업체:
Siemens
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Siemens

Series

6XV

Product Type

Ethernet Cable

Cable Length

10m

LAN Category

Cat6a

Terminated/Unterminated

Terminated

Shield Type

Shielded

Jacket Colour

Green

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

80°C

Fire Behaviour

Flame Resistant

Standards/Approvals

CE

Voltage

80V

Number of Cores

8

Outside Diameter

600μm

COO (Country of Origin):
SK

Siemens 6XV Series Ethernet Cable, 10m Cable Length, Shielded - 6XV18785BN10


This Ethernet cable is a prefabricated, terminated Cat6a patch lead intended for industrial Ethernet connections with RJ45 interfaces. It supports data rates from 10 Mbps up to 10,000 Mbps and is designed for use where a slim, shielded connection is required. The green-sheathed cable is suitable for harsh ambient conditions and PoE variants, providing a ready-to-use link between networked devices.

Features and Benefits:


• 10 m length delivers ready-made connectivity without on-site termination
• Shielded SF/UTP construction reduces external electromagnetic interference
• 80 V RMS rating supports PoE and powered network devices
• Flame‑resistant sheath meets IEC 60332-3-24 Category C safety
• Operating range -40 °C to +80 °C enables extreme temperature use

Applications


• Suitable for industrial switches requiring Cat6a performance
• Used with RJ45 equipment in factory Ethernet networks
• Ideal for PoE cameras and access points in cabinets
• Can be used for high-speed backbone links in control panels
• Used for shielded connections where EMI is present

What connector type is fitted to the cable?


It is supplied with two 180° RJ45 plugs terminated on each end.

How is the cable shield constructed?


The conductor bundle is wrapped in overlapped aluminium-clad foil with a tinned copper braided shield.

What conductor and insulation materials are used?


Insulated conductors are polyethylene with an FRNC inner sheath and PVC outer sheath.

How does the cable perform at high frequencies?


Attenuation is specified up to 500 MHz with measured values such as 0.287 dB/m at 100 MHz and 0.679 dB/m at 500 MHz.