Belden, 500 m Cat6a Cat6A Cable, Blue Unterminated to Unterminated Low Smoke Zero Halogen Sheath, S/FTP

Subtotal (1 reel of 500 metres)*

₩2,124,831.15

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 7월 13일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당
릴당
미터당*
1 +₩2,124,831.15₩4,249.05

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
631-680
제조사 부품 번호:
10GXE92.06500
제조업체:
Belden
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Belden

Product Type

Cat6A Cable

LAN Category

Cat6a

Cable Length

500m

Shield Type

S/FTP

Connector Type A

Unterminated

Connector Type B

Unterminated

Jacket Colour

Blue

Jacket Material

Low Smoke Zero Halogen

Standards/Approvals

EU, CE, ISO/IEC 11801-1, IEC 62821

Series

10GXE92

Voltage

72V

COO (Country of Origin):
HU

Belden Power Cable Assembly, 500m Cable Length, Blue Jacket - 10GXE92.06500


This power cable assembly provides long-range, shielded electrical transmission for industrial and automation settings. Designed for installations where reduced-hazard materials and extended cable runs are required, it connects equipment over a continuous 500 m length while supporting low-voltage power distribution up to 72 V. The jacket's halogen-free composition reduces harmful emissions in the event of fire, making it suitable for indoor and confined-space environments that demand safer cable materials.

Features & Benefits


• 500 m continuous length supports long-distance installations
• S/FTP shielding reduces electromagnetic interference on supply lines
• Low smoke zero halogen jacket limits toxic gas output during combustion
• Blue sheath enables Visual identification in complex cable routes
• Unterminated ends allow custom termination to specific connectors
• Rated for 72V operation suitable for low-voltage networks

**Applications**


• Suitable for industrial power distribution across factory floors
• Ideal for automation bus runs between control cabinets
• Used for connecting electrical equipment in confined public spaces
• Can be used for machinery power feeds requiring halogen-free materials
• Used with shielded signal systems where EMI control is required

How should the cable be prepared for connection to Terminal blocks?


Strip the outer sheath to expose the foil and braid, maintain shield continuity by folding the braid back over the jacket and ensure individual conductors are terminated with appropriate lugs or ferrules for secure clamping.

What environmental safety characteristics does it offer during a fire?


The halogen-free compound emits substantially lower corrosive gases and smoke density compared with standard PVC, reducing risk to nearby electronics and personnel evacuation visibility.

How does the shield configuration affect grounding practice?


The S/FTP construction provides an overall braided shield with individually screened pairs, so grounding at a single point or using a managed grounding scheme minimises ground loop formation while preserving EMI attenuation.

Are there considerations for routing given the cable’s length?


For continuous 500 m runs, plan for mechanical support to prevent strain, avoid Sharp bends that exceed manufacturer bend-radius limits, and include segregation from high-voltage lines to maintain signal integrity.

What voltage limitations should be observed during specification?


The assembly is intended for systems operating up to 72 V, so it should not be applied in higher-voltage circuits to prevent insulation breakdown and safety hazards.