Alpha Wire DEF STAN Control Cable, 6 Cores, 0.35mm² 22 AWG, Screened, 100 ft, White Polytetrafluoroethylene Sheath

Subtotal (1 reel of 30 metres)*

₩1,265,154.15

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 5월 11일 부터 2 개 단위 배송
  • 추가로 2026년 6월 30일 부터 7 개 단위 배송
  • 추가로 2026년 10월 06일 부터 3 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당
릴당
미터당*
1 +₩1,265,154.15₩42,172.65

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
277-5618
제조사 부품 번호:
2824/6 WH005
제조업체:
Alpha Wire
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Alpha Wire

Product Type

Control Cable

Series

DEF STAN

Number of Cores

6

Conductor Material

Silver Plated Copper

Jacket Material

Polytetrafluoroethylene

Jacket Colour

White

Armoured

No

Screened/Unscreened

Screened

Cable Length

100ft

Outside Diameter

0.211in

Voltage

600Vrms

Minimum Operating Temperature

-55°C

Maximum Operating Temperature

200°C

Standards/Approvals

EU Low Voltage 2014/35/EU, MIL W 16878/4 (Type E) 200°C / 600 VRMS, NEMA HP3 EXBFE 200°C / 600 VRMS

Hazardous Area Certification

No

Cable CSA

0.35mm²

American Wire Gauge

22AWG

Core Strands

19

제외

Belden Alpha Essentials Communication & Control Series Control Cable, 600Vrms Voltage, White Jacket - 2824/6 WH005


This control cable is a screened, six-core PTFE assembly designed for demanding electrical and automation environments where elevated temperature performance and stable signal integrity are required. It combines fine-stranded silver-plated copper conductors with a white PTFE outer tape to provide continuous operation across a wide temperature span while maintaining a 600Vrms rating for control circuits.

Features & Benefits


• Silver-plated copper conductors ensure low contact resistance and corrosion resistance
• 19-strand construction delivers enhanced flexibility for routing and installation
• Screened braid with ≥90% coverage reduces electromagnetic interference susceptibility
• PTFE insulation and jacket permit continuous use up to 200°C
• Voltage rating of 600Vrms supports typical control and signalling systems
• Minimum operating temperature of -55°C allows use in cold environments

**Applications**


• Suitable for wiring temperature-critical control panels in industrial automation
• Ideal for interconnects in electrical machinery operating at elevated temperatures
• Used with instrumentation and control equipment requiring screened cables
• Can be used for signal transmission in robotics and motion-control systems
• Suitable for retrofit installations needing a white PTFE jacket for identification

How is the core arrangement configured inside the assembly?


Six individually insulated conductors are cabled together with a specified twist rate and arranged from the inner layer outwards to maintain consistent geometry and electrical behaviour.

What mechanical limits should be observed during installation?


A recommended minimum bend radius equals ten times the cable diameter and pull tension should not exceed 41 lb to avoid conductor or insulation damage.

How does the shield affect grounding and continuity measurements?


The braided silver-plated copper shield presents an overall shield DC resistance of approximately 3.6 Ω/1000 ft at 20°C and is intended for use as a ground continuity path and EMI barrier.

What electrical characteristics influence signal performance over distance?


Typical conductor-to-conductor capacitance is around 24.1 pF/ft and inductance about 0.17 μH/ft, values useful for predicting signal propagation and coupling in control circuits.

Are there specific packaging lengths available for procurement?


The product is supplied in continuous 100 ft lengths and larger reels with a minimum piece length of 100 ft when provided in multiple sections.