Alpha Wire XTRA-GUARD 2 Control Cable, 4 Cores, 0.81mm² 18 AWG, Unscreened, 30 m, Black Polyvinyl Chloride Sheath
- RS 제품 번호:
- 409-268
- 제조사 부품 번호:
- 25064 BK005
- 제조업체:
- Alpha Wire
Subtotal (1 reel of 30 metres)*
₩691,100.00
재고있음
- 9 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩691,100.00 | ₩23,036.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 409-268
- 제조사 부품 번호:
- 25064 BK005
- 제조업체:
- Alpha Wire
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Alpha Wire | |
| Product Type | Control Cable | |
| Series | XTRA-GUARD 2 | |
| Number of Cores | 4 | |
| Conductor Material | Tin Copper Wire | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Black | |
| Armoured | Yes | |
| Screened/Unscreened | Unscreened | |
| Outside Diameter | 6.58mm | |
| Cable Length | 30m | |
| Voltage | 300V | |
| Minimum Operating Temperature | -30°C | |
| Maximum Operating Temperature | 90°C | |
| Standards/Approvals | CE, CSA, UL | |
| Cable CSA | 0.81mm² | |
| Hazardous Area Certification | No | |
| American Wire Gauge | 18AWG | |
| Fire Behaviour | Flame Retardant | |
| Core Strands | 16 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Alpha Wire | ||
Product Type Control Cable | ||
Series XTRA-GUARD 2 | ||
Number of Cores 4 | ||
Conductor Material Tin Copper Wire | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Black | ||
Armoured Yes | ||
Screened/Unscreened Unscreened | ||
Outside Diameter 6.58mm | ||
Cable Length 30m | ||
Voltage 300V | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature 90°C | ||
Standards/Approvals CE, CSA, UL | ||
Cable CSA 0.81mm² | ||
Hazardous Area Certification No | ||
American Wire Gauge 18AWG | ||
Fire Behaviour Flame Retardant | ||
Core Strands 16 | ||
Belden XTRA-GUARD 2 Series Control Cable, 30m Cable Length, 4 Cores - 25064 BK005
This control cable provides multi-core signal and control connectivity for industrial and automation systems. Engineered for environments requiring compact, flexible cabling, it combines tinned copper conductors with a robust outer sheath to deliver safe operation up to moderate temperatures and voltages.
Features & Benefits
• Four tinned copper conductors for corrosion resistance and continuity
• 300V rating enabling use in typical control circuits
• Flame-retardant outer jacket reducing fire propagation risk
• Temperature endurance from -30 to 90°C for varied environments
• Unscreened design offering flexibility and reduced weight
• 6.58mm outside diameter for space-efficient installations
• 300V rating enabling use in typical control circuits
• Flame-retardant outer jacket reducing fire propagation risk
• Temperature endurance from -30 to 90°C for varied environments
• Unscreened design offering flexibility and reduced weight
• 6.58mm outside diameter for space-efficient installations
**Applications**
• Suitable for wiring control panels in manufacturing equipment
• Ideal for interconnecting sensors and actuators on production lines
• Used with motor starters and relay cabinets in automation systems
• Can be used for signal runs in building management systems
• Ideal for interconnecting sensors and actuators on production lines
• Used with motor starters and relay cabinets in automation systems
• Can be used for signal runs in building management systems
What conductor construction is used to maintain signal integrity?
Each core comprises multiple tinned copper strands arranged as 16-strand conductors to balance flexibility with low resistance.
How is the cable assembled to ensure stable core positioning?
The four insulated cores are cabled with a minimum twist rate and wrapped with non‑woven polyester tape to maintain component orientation and reduce movement.
What mechanical handling limits should installers observe during routing?
Minimum bend radius is ten times the cable diameter and maximum pull tension is 50 lb to avoid conductor or jacket damage.
Which sheath material and colours are available for identification?
The jacket is a polyvinyl chloride formulation supplied in black and other colour options for easy coding on site.
How are capacitance and inductance specified for system design?
Typical conductor-to-conductor capacitance is 30 pF/ft and nominal inductance is 0.18 μH/ft for electrical design calculations.
관련된 링크들
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 2 Cores, 0.81mm² 18 AWG, Unscreened, 30 m, Black Polyvinyl
- Alpha Wire XTRA-GUARD 2 Control Cable, 6 Cores, 0.81mm² 18 AWG, Unscreened, 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 6 Cores, 0.35mm² 22 AWG, Unscreened, 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 3 Cores, 0.23mm² 24 AWG, Unscreened, 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 6 Cores, 0.23mm² 24 AWG, Unscreened, 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 8 Cores, 0.56mm² 20 AWG, Unscreened, 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 4 Cores, 0.23mm² 24 AWG, Unscreened, 30 m, Black Polyethylene
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable, 10 Cores, 0.35mm² 22 AWG, Unscreened, 30 m, Black Polyvinyl