ABB, 16 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- RS 제품 번호:
- 266-4486
- 제조사 부품 번호:
- 7TCA296100R0169
- 제조업체:
- ABB
Subtotal (1 reel of 25 metres)*
₩5,525,695.50
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩5,525,695.50 | ₩221,028.60 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 266-4486
- 제조사 부품 번호:
- 7TCA296100R0169
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Product Type | Flexible Conduit | |
| Nominal Diameter | 16mm | |
| Coating Material | Thermoplastic Rubber Extreme Temperature | |
| Material | Galvanised Steel | |
| Series | Adaptaflex | |
| Colour | Black | |
| Length | 25m | |
| IP Rating | IP68, IP69 | |
| Thread Size | 69 mm | |
| Minimum Operating Temperature | -50°C | |
| Resistance Features | Liquid Resistant | |
| Maximum Operating Temperature | 130°C | |
| Standards/Approvals | CE, RoHS, REACH | |
| Hazardous Area Certification | ATEX | |
| Minimum Bend Radius | 80mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Product Type Flexible Conduit | ||
Nominal Diameter 16mm | ||
Coating Material Thermoplastic Rubber Extreme Temperature | ||
Material Galvanised Steel | ||
Series Adaptaflex | ||
Colour Black | ||
Length 25m | ||
IP Rating IP68, IP69 | ||
Thread Size 69 mm | ||
Minimum Operating Temperature -50°C | ||
Resistance Features Liquid Resistant | ||
Maximum Operating Temperature 130°C | ||
Standards/Approvals CE, RoHS, REACH | ||
Hazardous Area Certification ATEX | ||
Minimum Bend Radius 80mm | ||
제외
- COO (Country of Origin):
- GB
ABB Adaptaflex Series Flexible Conduit, 16mm Nominal Diameter, 25m Length - 7TCA296100R0169
This flexible conduit provides robust cable protection for demanding industrial environments, combining a galvanised steel core with a thermoplastic rubber outer layer to withstand harsh conditions. Designed for use where ingress protection and hazardous-area certification matter, it offers a long 25 m length and suitability across a wide ambient temperature range to support installations in automation, electrical and mechanical systems.
Features and Benefits:
• Rated to IP68 IP69 for reliable dust and water ingress resistance
• Thermoplastic rubber withstands -50 to 130°C for extreme environments
• Galvanised steel construction offers mechanical protection against impact
• ATEX certified for use in potentially explosive atmospheres
• Liquid-resistant outer coating reduces maintenance in wet conditions
• 69mm thread size enables secure connections to compatible fittings
• Thermoplastic rubber withstands -50 to 130°C for extreme environments
• Galvanised steel construction offers mechanical protection against impact
• ATEX certified for use in potentially explosive atmospheres
• Liquid-resistant outer coating reduces maintenance in wet conditions
• 69mm thread size enables secure connections to compatible fittings
Applications
• Suitable for power and signal routing in automation cabinets
• Ideal for electrical installations within hazardous zones
• Used for cable protection on machinery exposed to liquids
• Can be used in outdoor installations requiring high ingress protection
• Suitable for retrofit of industrial control panels needing Durable sleeving
• Ideal for electrical installations within hazardous zones
• Used for cable protection on machinery exposed to liquids
• Can be used in outdoor installations requiring high ingress protection
• Suitable for retrofit of industrial control panels needing Durable sleeving
What temperature extremes can it tolerate in continuous operation?
It operates across a wide range from -50°C up to a maximum of 130°C to accommodate cold stores and high-heat process areas.
How does its construction affect resistance to physical damage?
The internal galvanised steel provides structural strength and abrasion resistance while the outer thermoplastic rubber adds impact damping and chemical resistance.
What approvals support its use in regulated installations?
It carries CE, RoHS and REACH approvals and has ATEX certification for hazardous environments.
How long is each supply length and how does that aid installation?
Each length measures 25 m, allowing long continuous runs to reduce jointing and speed installation in large plants.
What conduit diameter and routing constraints should be considered?
The nominal internal diameter is 16mm and the minimum bend radius is 80mm, which should be observed when planning cable routing.
관련된 링크들
- ABB, 25 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- ABB, 32 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- ABB, 20 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- ABB, 16 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- ABB, 40 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- Adaptaflex, 25 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- Adaptaflex, 20 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
- Adaptaflex, 16 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black