ABB, 32 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- RS 제품 번호:
- 266-4473
- 제조사 부품 번호:
- 7TCA296030R0516
- 제조업체:
- ABB
Subtotal (1 reel of 25 metres)*
₩5,657,047.50
제조사가 재고 비축중
- 2026년 6월 18일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩5,657,047.50 | ₩226,281.90 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 266-4473
- 제조사 부품 번호:
- 7TCA296030R0516
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Nominal Diameter | 32mm | |
| Product Type | Flexible Conduit | |
| Coating Material | High Temperature Thermoplastic | |
| Material | Galvanised Steel | |
| Series | Adaptaflex | |
| Colour | White | |
| Length | 25m | |
| IP Rating | IP40, IP69 | |
| Thread Size | 16 mm | |
| Minimum Operating Temperature | -50°C | |
| Resistance Features | Liquid Resistant | |
| Maximum Operating Temperature | 130°C | |
| Standards/Approvals | REACH, RoHS, CE | |
| Hazardous Area Certification | ATEX | |
| Minimum Bend Radius | 80mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Nominal Diameter 32mm | ||
Product Type Flexible Conduit | ||
Coating Material High Temperature Thermoplastic | ||
Material Galvanised Steel | ||
Series Adaptaflex | ||
Colour White | ||
Length 25m | ||
IP Rating IP40, IP69 | ||
Thread Size 16 mm | ||
Minimum Operating Temperature -50°C | ||
Resistance Features Liquid Resistant | ||
Maximum Operating Temperature 130°C | ||
Standards/Approvals REACH, RoHS, CE | ||
Hazardous Area Certification ATEX | ||
Minimum Bend Radius 80mm | ||
제외
- COO (Country of Origin):
- GB
ABB Adaptaflex Series Flexible Conduit, 32mm Nominal Diameter, White - 7TCA296030R0516
This flexible conduit provides protected routing for cables and wiring in demanding industrial environments. Designed for use where elevated temperatures, liquid exposure and regulatory compliance are considerations, it combines a galvanised steel core with a high-temperature thermoplastic outer layer to maintain mechanical integrity and environmental resistance across harsh duty cycles.
Features and Benefits:
• Withstands continuous use up to 130°C for high-temperature applications
• Operates down to -50°C for cold-environment installation reliability
• Offers liquid resistance to protect conductors in wet conditions
• Complies with REACH and RoHS to meet materials restrictions
• Supplied in a 25 m length for extended runs without joins
• IP40 and IP69 ratings for protection against ingress and washdown
• Operates down to -50°C for cold-environment installation reliability
• Offers liquid resistance to protect conductors in wet conditions
• Complies with REACH and RoHS to meet materials restrictions
• Supplied in a 25 m length for extended runs without joins
• IP40 and IP69 ratings for protection against ingress and washdown
Applications
• Suitable for automation cabinets exposed to heat and moisture
• Ideal for routing cables in food processing washdown areas
• Used with electrical installations requiring hazardous-area certification
• Can be used for machinery wiring where low-temperature resilience is needed
• Ideal for routing cables in food processing washdown areas
• Used with electrical installations requiring hazardous-area certification
• Can be used for machinery wiring where low-temperature resilience is needed
What construction provides mechanical protection against impact?
The conduit uses a galvanised steel inner structure that gives crush and impact resistance while allowing flexibility for routed runs.
How is attachment to equipment achieved where threads are needed?
The product accepts fittings with a 16mm thread size to enable secure connections to glands and enclosures.
Which environmental standards govern suitability for explosive atmospheres?
It holds an ATEX hazardous-area certification indicating it meets required safety criteria for specified explosive atmospheres.
How does the conduit cope with regulatory material limits?
The materials used conform to REACH and RoHS standards, restricting certain hazardous substances in components.
What diameters and bend characteristics affect routing in confined spaces?
The conduit has a 32mm nominal diameter and requires a minimum bend radius of 80mm to preserve cable integrity.
관련된 링크들
- ABB, 26.4 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 16 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 25 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 32 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 20 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 17.8 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- ABB, 21.1 mm Nominal Diameter, High Temperature Thermoplastic, Galvanised Steel, White
- Adaptaflex, 25 mm Nominal Diameter, Thermoplastic Rubber Extreme Temperature, Galvanised Steel, Black
