ABB, 40 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Black
- RS 제품 번호:
- 266-4458
- 제조사 부품 번호:
- 7TCA296030R0270
- 제조업체:
- ABB
Subtotal (1 reel of 25 metres)*
₩2,248,720.50
제조사가 재고 비축중
- 2026년 6월 16일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩2,248,720.50 | ₩89,949.60 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 266-4458
- 제조사 부품 번호:
- 7TCA296030R0270
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Nominal Diameter | 40mm | |
| Product Type | Flexible Conduit | |
| Coating Material | Polyvinyl Chloride | |
| Material | Galvanised Steel | |
| Series | Adaptaflex | |
| Colour | Black | |
| Length | 25m | |
| IP Rating | IP68, IP69 | |
| Thread Size | 70 mm | |
| Resistance Features | Liquid Resistant | |
| Minimum Operating Temperature | -50°C | |
| Maximum Operating Temperature | 130°C | |
| Hazardous Area Certification | ATEX | |
| Standards/Approvals | REACH, CE, RoHS | |
| Minimum Bend Radius | 80mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Nominal Diameter 40mm | ||
Product Type Flexible Conduit | ||
Coating Material Polyvinyl Chloride | ||
Material Galvanised Steel | ||
Series Adaptaflex | ||
Colour Black | ||
Length 25m | ||
IP Rating IP68, IP69 | ||
Thread Size 70 mm | ||
Resistance Features Liquid Resistant | ||
Minimum Operating Temperature -50°C | ||
Maximum Operating Temperature 130°C | ||
Hazardous Area Certification ATEX | ||
Standards/Approvals REACH, CE, RoHS | ||
Minimum Bend Radius 80mm | ||
제외
- COO (Country of Origin):
- GB
ABB Adaptaflex Series Flexible Conduit, 40mm Nominal Diameter, Black - 7TCA296030R0270
This flexible conduit provides protected routing for cables in demanding industrial environments, combining a steel inner structure with a protective polymer outer layer to resist liquids and environmental ingress. It is intended for installations requiring robust mechanical shielding and high ingress protection ratings, suitable for use where temperature extremes and hazardous atmospheres are present.
Features and Benefits:
• Galvanised steel core with PVC coating offers mechanical protection and corrosion resistance
• IP68 and IP69 rating ensures continuous immersion and high-pressure washdown resistance
• ATEX certification permits use in certain hazardous atmospheres
• Operates from -50°C to 130°C for wide thermal-range deployments
• REACH, RoHS and CE conformity supports regulatory compatibility in industrial sites
• Minimum bend radius 80mm permits flexible routing in tight assemblies
• IP68 and IP69 rating ensures continuous immersion and high-pressure washdown resistance
• ATEX certification permits use in certain hazardous atmospheres
• Operates from -50°C to 130°C for wide thermal-range deployments
• REACH, RoHS and CE conformity supports regulatory compatibility in industrial sites
• Minimum bend radius 80mm permits flexible routing in tight assemblies
Applications
• Suitable for cable routing in automation cabinets exposed to washdown
• Ideal for electrical installations within hazardous-area zones
• Used for protecting sensor and actuator cabling in process plants
• Can be used for interconnections on mobile machinery subject to temperature extremes
• Used with outdoor control enclosures requiring liquid-resistant conduits
• Ideal for electrical installations within hazardous-area zones
• Used for protecting sensor and actuator cabling in process plants
• Can be used for interconnections on mobile machinery subject to temperature extremes
• Used with outdoor control enclosures requiring liquid-resistant conduits
What material combinations provide the conduits mechanical and external protection?
A galvanised steel inner structure delivers tensile and crush resistance while a polyvinyl chloride outer layer provides chemical resistance and a protective sheath.
How long is the product and what does that mean for installation planning?
It is supplied in a 25 m length allowing extended continuous runs without joints, reducing potential leak paths and installation labour.
Which thread size should be accommodated when terminating the conduit?
The conduit is designed for a 70mm thread size, so gland and entry fittings must match that dimension.
How does the conduit perform in high-temperature operations?
The assembly remains functional up to 130°C, enabling use near heat-generating equipment and in elevated-temperature process areas.
관련된 링크들
- ABB, 16 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Black
- ABB, 25 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Grey
- ABB, 16 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Grey
- ABB, 20 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Grey
- ABB, 32 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Grey
- ABB, 50 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Black
- ABB, 32 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Black
- ABB, 20 mm Nominal Diameter, Polyvinyl Chloride, Galvanised Steel, Black