HellermannTyton, 10 mm Nominal Diameter, Galvanised Steel, Metal
- RS 제품 번호:
- 433-480
- 제조사 부품 번호:
- 166-30110
- 제조업체:
- HellermannTyton
Subtotal (1 reel of 10 metres)*
₩54,678.00
재고있음
- 추가로 2026년 5월 11일 부터 11 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩54,678.00 | ₩5,467.80 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 433-480
- 제조사 부품 번호:
- 166-30110
- 제조업체:
- HellermannTyton
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | HellermannTyton | |
| Nominal Diameter | 10mm | |
| Product Type | Flexible Conduit | |
| Material | Galvanised Steel | |
| Series | SC10 | |
| Colour | Metal | |
| Length | 10m | |
| IP Rating | IP40 | |
| Minimum Operating Temperature | -100°C | |
| Resistance Features | Acid Resistant, Abrasion Resistant, Impact Resistant, High Mechanical Strength, Oil Resistant, Low Toxicity, Low Smoke, Flame Retardant, Sulphur Free | |
| Maximum Operating Temperature | 300°C | |
| Hazardous Area Certification | No | |
| Standards/Approvals | IEC 61386, UL 94 V0, EN IEC 61386, UL 94 HB, UL 94 V2 | |
| Minimum Bend Radius | 25mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 HellermannTyton | ||
Nominal Diameter 10mm | ||
Product Type Flexible Conduit | ||
Material Galvanised Steel | ||
Series SC10 | ||
Colour Metal | ||
Length 10m | ||
IP Rating IP40 | ||
Minimum Operating Temperature -100°C | ||
Resistance Features Acid Resistant, Abrasion Resistant, Impact Resistant, High Mechanical Strength, Oil Resistant, Low Toxicity, Low Smoke, Flame Retardant, Sulphur Free | ||
Maximum Operating Temperature 300°C | ||
Hazardous Area Certification No | ||
Standards/Approvals IEC 61386, UL 94 V0, EN IEC 61386, UL 94 HB, UL 94 V2 | ||
Minimum Bend Radius 25mm | ||
제외
- COO (Country of Origin):
- GB
HellermanTyton SC10 Series Flexible Conduit, 10mm Nominal Diameter, 10m Length - 166-30110
This flexible conduit provides a metal protective route for cable runs in demanding industrial environments. It is designed to shield wiring from mechanical stress and chemical exposure while maintaining functionality across a wide temperature range. The product is intended for use where a Durable metallic conduit is required to preserve cable integrity and facilitate installation in automation, electrical and mechanical systems.
Features & Benefits
• Galanised steel construction offers enhanced mechanical protection and longevity
• Withstands continuous temperatures up to 300°C for high-heat installations
• Resistant to acids and oils to reduce chemical degradation risk
• Low smoke and sulphur-free composition minimises harmful emissions in fires
• Impact and abrasion resistance reduces maintenance and replacement frequency
• Meets flame-retardant requirements UL94 V0 supporting safer system design
• Withstands continuous temperatures up to 300°C for high-heat installations
• Resistant to acids and oils to reduce chemical degradation risk
• Low smoke and sulphur-free composition minimises harmful emissions in fires
• Impact and abrasion resistance reduces maintenance and replacement frequency
• Meets flame-retardant requirements UL94 V0 supporting safer system design
**Applications**
• Suitable for routing cables in factory automation cabinets and enclosures
• Ideal for protecting harnesses in electrical distribution panels
• Used with sensor and actuator wiring in robotics installations
• Can be used for cable protection where high-temperature exposure occurs
• Suitable for installations requiring reduced-smoke materials in confined spaces
• Ideal for protecting harnesses in electrical distribution panels
• Used with sensor and actuator wiring in robotics installations
• Can be used for cable protection where high-temperature exposure occurs
• Suitable for installations requiring reduced-smoke materials in confined spaces
What ingress protection rating does it provide against solids and liquids?
The conduit carries an IP40 classification which indicates protection against solid objects greater than 1 mm but not against water jets, so additional sealing is needed for wet environments.
How flexible is the conduit for tight routing?
It accommodates bends down to a minimum bend radius of 25 mm, allowing Compact routing while maintaining conductor protection.
Which standards govern its construction and flammability performance?
Manufacturing and dimensional characteristics align with IEC 61386 and EN IEC 61386, while flammability classifications include UL94 V0, UL94 HB and UL94 V2.
What length and internal diameter are supplied for typical installation planning?
Units are supplied in 10 m lengths with a nominal internal diameter of 10 mm to assist in cable planning and run estimates.
관련된 링크들
- HellermannTyton, 10 mm Nominal Diameter, Galvanised Steel, Grey
- HellermannTyton, 63 mm Nominal Diameter, Galvanised Steel, Grey
- HellermannTyton, 25 mm Nominal Diameter, Galvanised Steel, Grey
- HellermannTyton, 32 mm Nominal Diameter, Galvanised Steel, Grey
- HellermannTyton, 20 mm Nominal Diameter, Galvanised Steel, Grey
- HellermannTyton, 16 mm Nominal Diameter, Galvanised Steel, Grey
- HellermannTyton, 50 mm Nominal Diameter, Galvanised Steel, Grey
- HellermannTyton, 40 mm Nominal Diameter, Galvanised Steel, Grey