모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Fluke | |
| Absolute Maximum AC Current Measurement | 2.5kA ac | |
| Absolute Maximum DC Current Measurement | 600A dc | |
| Absolute Maximum AC Voltage Measurement | 600V ac | |
| Absolute Maximum DC Voltage Measurement | 600V dc | |
| Absolute Maximum Resistance Measurement | 6kΩ | |
| Model Number | 374 | |
| AC Current Measurement Resolution | 100mA ac | |
| DC Current Measurement Resolution | 100mA dc | |
| Best DC Current Accuracy | ±2% + 5 Digits | |
| Clamp Meter Type | Capacitance, Continuity, Current, Resistance, Voltage | |
| Best AC Current Accuracy | ±2% +5 digits | |
| Best AC Voltage Accuracy | ±1.5% + 5 Digits | |
| Best DC Voltage Accuracy | ±1% + 5 Digits | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Resistance | |
| True RMS | Yes | |
| Maximum Conductor Size | 34mm | |
| AC Voltage Measurement Range | 600 V ac | |
| DC Voltage Measurement Resolution | 0.1V dc | |
| Resistance Measurement Resolution | 100mΩ | |
| Dimensions | 248 x 85 x 45mm | |
| DC Current Measurement Range | Maximum of 600 A dc | |
| Width | 85mm | |
| AC Current Measurement Range | Maximum of 2500 A ac | |
| Weight | 375g | |
| Maximum Operating Temperature | 50°C | |
| Safety Category Level | CAT II, CAT IV | |
| Safety Category Voltage | 600 V, 1000 V | |
| Battery Type | AA | |
| Safety Category | CAT III 1000 V, CAT IV 600 V | |
| Best Resistance Measurement Accuracy | ±1% + 5 Digits | |
| Display Type | LCD | |
| Power Source | Battery | |
| Length | 248mm | |
| AC Voltage Measurement Resolution | 0.1V ac | |
| Minimum Operating Temperature | -10°C | |
| Height | 45mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Fluke | ||
Absolute Maximum AC Current Measurement 2.5kA ac | ||
Absolute Maximum DC Current Measurement 600A dc | ||
Absolute Maximum AC Voltage Measurement 600V ac | ||
Absolute Maximum DC Voltage Measurement 600V dc | ||
Absolute Maximum Resistance Measurement 6kΩ | ||
Model Number 374 | ||
AC Current Measurement Resolution 100mA ac | ||
DC Current Measurement Resolution 100mA dc | ||
Best DC Current Accuracy ±2% + 5 Digits | ||
Clamp Meter Type Capacitance, Continuity, Current, Resistance, Voltage | ||
Best AC Current Accuracy ±2% +5 digits | ||
Best AC Voltage Accuracy ±1.5% + 5 Digits | ||
Best DC Voltage Accuracy ±1% + 5 Digits | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Resistance | ||
True RMS Yes | ||
Maximum Conductor Size 34mm | ||
AC Voltage Measurement Range 600 V ac | ||
DC Voltage Measurement Resolution 0.1V dc | ||
Resistance Measurement Resolution 100mΩ | ||
Dimensions 248 x 85 x 45mm | ||
DC Current Measurement Range Maximum of 600 A dc | ||
Width 85mm | ||
AC Current Measurement Range Maximum of 2500 A ac | ||
Weight 375g | ||
Maximum Operating Temperature 50°C | ||
Safety Category Level CAT II, CAT IV | ||
Safety Category Voltage 600 V, 1000 V | ||
Battery Type AA | ||
Safety Category CAT III 1000 V, CAT IV 600 V | ||
Best Resistance Measurement Accuracy ±1% + 5 Digits | ||
Display Type LCD | ||
Power Source Battery | ||
Length 248mm | ||
AC Voltage Measurement Resolution 0.1V ac | ||
Minimum Operating Temperature -10°C | ||
Height 45mm | ||
- COO (Country of Origin):
- CN
Fluke Clamp Meter, 600V Maximum AC Voltage Measurement, 34mm Maximum Jaw Opening - 3790599
Features and Benefits:
• Measures up to 600V AC and 600V DC for versatile use
• 2% AC current accuracy with 0.1A resolution for precise current checks
• 1% DC voltage accuracy for high‑accuracy DC voltage measurement
• 34mm jaw opening clamp for conductors of varied sizes
• Backlit display for readability in low‑light conditions
Applications
• Used for maintenance on building electrical distribution
• Ideal for measuring DC supplies in battery systems
• Can be used for verifying capacitance and resistance values
• Used with portable test kits for on‑site electrical diagnostics
What power source does it use and how does that affect field work?
What safety ratings support use near distribution panels?
Which measurements does it cover beyond current and voltage?
How well does it resolve small resistance and current changes?
관련된 링크들
- Fluke 374 Clamp Meter, 600 A dc 600 A ac 600 V dc 600 V ac CAT IV, CAT III
- Fluke 374 FC Clamp Meter, 600 A 2.5 kA 600 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- Fluke 375 Clamp Meter, 600 A dc 600 A ac 600 V dc CAT III, CAT IV
- Fluke 325 Clamp Meter 400 A 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 323 Clamp Meter 400 A 600 V dc 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 353 Clamp Meter, 2000 A dc 2000 A ac CAT III, CAT IV
- Fluke 324 Clamp Meter, 400 A 400 A 600 V dc 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke A3002 FC Clamp Meter, 1 kA 600 A CAT IV, CAT III Non-Contact Voltage Detector