Fluke 381 Clamp Meter, 1000 A dc 2.5 kA 1000 V dc 1000 V ac CAT IV, CAT III Non-Contact Voltage Detector
- RS 제품 번호:
- 705-1923
- Distrelec 제품 번호:
- 176-43-494
- 제조사 부품 번호:
- FLUKE 381
- 제조업체:
- Fluke
Subtotal (1 unit)*
₩1,739,520.00
- 2027년 1월 12일 부터 배송 준비 완료
수량 | 한팩당 |
|---|---|
| 1 + | ₩1,739,520.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 705-1923
- Distrelec 제품 번호:
- 176-43-494
- 제조사 부품 번호:
- FLUKE 381
- 제조업체:
- Fluke
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 1000A dc | |
| Resistance Resolution | 100mΩ | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60kΩ | |
| Model Number | 381 | |
| DC Voltage Resolution | 100 mV dc | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| Resistance Measurement Accuracy | ± 1 % ± 5 Digits | |
| AC Current Resolution | 100mA | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Clamp Meter Type | Continuity, Current, Frequency, Resistance, Voltage | |
| AC Voltage Resolution | 100mV ac | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| Minimum Operating Temperature | -10°C | |
| Maximum Jaw Opening | 34mm | |
| Maximum Operating Temperature | 50°C | |
| Height | 50mm | |
| Length | 277mm | |
| Width | 88mm | |
| Standards/Approvals | RoHS | |
| Weight | 540g | |
| True RMS | Yes | |
| Functions Measured | Resistance, AC Voltage, Continuity, DC Current, Frequency, AC Current, DC Voltage | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Level | CAT IV, CAT III | |
| Battery Type | AA | |
| Maximum AC Current Measurement | 2.5kA | |
| Safety Category Voltage | 600V, 1V | |
| Power Source | Battery | |
| Display Type | LCD | |
| Maximum Conductor Size | 7.5mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 1000A dc | ||
Resistance Resolution 100mΩ | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60kΩ | ||
Model Number 381 | ||
DC Voltage Resolution 100 mV dc | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
Resistance Measurement Accuracy ± 1 % ± 5 Digits | ||
AC Current Resolution 100mA | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Clamp Meter Type Continuity, Current, Frequency, Resistance, Voltage | ||
AC Voltage Resolution 100mV ac | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
Minimum Operating Temperature -10°C | ||
Maximum Jaw Opening 34mm | ||
Maximum Operating Temperature 50°C | ||
Height 50mm | ||
Length 277mm | ||
Width 88mm | ||
Standards/Approvals RoHS | ||
Weight 540g | ||
True RMS Yes | ||
Functions Measured Resistance, AC Voltage, Continuity, DC Current, Frequency, AC Current, DC Voltage | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Level CAT IV, CAT III | ||
Battery Type AA | ||
Maximum AC Current Measurement 2.5kA | ||
Safety Category Voltage 600V, 1V | ||
Power Source Battery | ||
Display Type LCD | ||
Maximum Conductor Size 7.5mm | ||
Fluke Clamp Meter, 999.9A Maximum DC Current, 600V Maximum AC Voltage - FLUKE 381
Features & Benefits
• 999.9A jaw current measurement for heavy conductor diagnostics
• 2500A iFlex™ flexible probe expands current capture capability
• True-rms acquisition for accurate readings on distorted waveforms
• Inrush capture to Record motor starting currents precisely
• Wireless removable display allows remote viewing up to 30 ft
**Applications**
• Ideal for motor start current analysis and maintenance checks
• Used for load studies and power quality assessments on non-linear systems
• Can be used for verifying supply presence with non-contact detection
• Used with awkward conductors where flexible probe access is required
What conductor sizes can be accommodated by the jaw and probe?
How does the instrument handle noisy industrial environments?
Which safety categories apply for field use on distribution systems?
What measurement functions are available beyond voltage and current?
What power source and display features support extended field use?
Supplied with
• 1 pair of TL75 test leads
• 1 pair of AC175 alligator clips
• 18-inch iFlex®flexible current probe
• Soft carrying case
관련된 링크들
- Fluke 376 Clamp Meter, 1000 A dc 1000 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- Fluke 355 Clamp Meter, 2 kA 2 kA 1000 V dc 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 325 Clamp Meter 400 A 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter, 999.9 A 999.9 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- Fluke 374 FC Clamp Meter, 600 A 2.5 kA 600 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter, 600 A 2.5 kA 600 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- Fluke 323 Clamp Meter 400 A 600 V dc 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke A3001 FC Clamp Meter 2.5 kA CAT IV, CAT III Non-Contact Voltage Detector