Fluke 381 Clamp Meter, 1000 A dc 2.5 kA 1000 V dc 1000 V ac CAT IV, CAT III Non-Contact Voltage Detector
- RS 제품 번호:
- 705-1923
- Distrelec 제품 번호:
- 176-43-494
- 제조사 부품 번호:
- FLUKE 381
- 제조업체:
- Fluke
Subtotal (1 unit)*
₩1,739,520.00
- 2026년 12월 04일 부터 배송 준비 완료
수량 | 한팩당 |
|---|---|
| 1 + | ₩1,739,520.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 705-1923
- Distrelec 제품 번호:
- 176-43-494
- 제조사 부품 번호:
- FLUKE 381
- 제조업체:
- Fluke
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Fluke | |
| Product Type | Clamp Meter | |
| Resistance Resolution | 100mΩ | |
| Maximum DC Current Measurement | 1000A dc | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60kΩ | |
| Model Number | 381 | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| Resistance Measurement Accuracy | ± 1 % ± 5 Digits | |
| AC Current Resolution | 100mA | |
| Minimum Operating Temperature | -10°C | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Maximum Jaw Opening | 34mm | |
| AC Voltage Resolution | 100mV ac | |
| Clamp Meter Type | Continuity, Current, Frequency, Resistance, Voltage | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| DC Voltage Resolution | 100 mV dc | |
| Maximum Operating Temperature | 50°C | |
| Weight | 540g | |
| Height | 50mm | |
| Standards/Approvals | RoHS | |
| Width | 88mm | |
| Length | 277mm | |
| Functions Measured | Resistance, AC Voltage, Continuity, DC Current, Frequency, AC Current, DC Voltage | |
| True RMS | Yes | |
| Maximum Conductor Size | 7.5mm | |
| Maximum AC Current Measurement | 2.5kA | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Level | CAT IV, CAT III | |
| Battery Type | AA | |
| Power Source | Battery | |
| Display Type | LCD | |
| Safety Category Voltage | 600V, 1V | |
| 모두 선택 | ||
|---|---|---|
브랜드 Fluke | ||
Product Type Clamp Meter | ||
Resistance Resolution 100mΩ | ||
Maximum DC Current Measurement 1000A dc | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60kΩ | ||
Model Number 381 | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
Resistance Measurement Accuracy ± 1 % ± 5 Digits | ||
AC Current Resolution 100mA | ||
Minimum Operating Temperature -10°C | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Maximum Jaw Opening 34mm | ||
AC Voltage Resolution 100mV ac | ||
Clamp Meter Type Continuity, Current, Frequency, Resistance, Voltage | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
DC Voltage Resolution 100 mV dc | ||
Maximum Operating Temperature 50°C | ||
Weight 540g | ||
Height 50mm | ||
Standards/Approvals RoHS | ||
Width 88mm | ||
Length 277mm | ||
Functions Measured Resistance, AC Voltage, Continuity, DC Current, Frequency, AC Current, DC Voltage | ||
True RMS Yes | ||
Maximum Conductor Size 7.5mm | ||
Maximum AC Current Measurement 2.5kA | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Level CAT IV, CAT III | ||
Battery Type AA | ||
Power Source Battery | ||
Display Type LCD | ||
Safety Category Voltage 600V, 1V | ||
Fluke Clamp Meter, 999.9A Maximum DC Current, 600V Maximum AC Voltage - FLUKE 381
Features & Benefits
• 999.9A jaw current measurement for heavy conductor diagnostics
• 2500A iFlex™ flexible probe expands current capture capability
• True-rms acquisition for accurate readings on distorted waveforms
• Inrush capture to Record motor starting currents precisely
• Wireless removable display allows remote viewing up to 30 ft
**Applications**
• Ideal for motor start current analysis and maintenance checks
• Used for load studies and power quality assessments on non-linear systems
• Can be used for verifying supply presence with non-contact detection
• Used with awkward conductors where flexible probe access is required
What conductor sizes can be accommodated by the jaw and probe?
How does the instrument handle noisy industrial environments?
Which safety categories apply for field use on distribution systems?
What measurement functions are available beyond voltage and current?
What power source and display features support extended field use?
Supplied with
• 1 pair of TL75 test leads
• 1 pair of AC175 alligator clips
• 18-inch iFlex®flexible current probe
• Soft carrying case
관련된 링크들
- Fluke 376 Clamp Meter, 999.9 A 2500 A 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter, 999.9 A 2500 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- Fluke 378 FC Clamp Meter, 999.9 A dc 2500 A ac 1000 V dc 1000 V ac CAT III 1000 V, CAT IV 600 V Non-Contact Voltage
- Fluke 393FC/E Clamp Meter, 999.9 A 999.9 A 1500 V dc 1000 V ac CAT III, CAT IV
- RS PRO Clamp Meter 999 A 1000 V dc 999 V ac CAT IV Non-Contact Voltage Detector
- Fluke A3001 FC Clamp Meter 2500 A CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 393/E Clamp Meter, 1000 A dc 2500 A ac 1500 V dc 1000 V ac CAT IV, CAT III
- Fluke 376 Clamp Meter, 999.9A dc, Max Current 2.5kA ac CAT III 1000 V, CAT IV 600 V