Fluke A283FC EUR Clamp Meter, 60 A 60 A 1500 V dc 1000 V ac CAT III, CAT IV

Subtotal (1 unit)*

₩702,480.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 2 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩702,480.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
191-773
제조사 부품 번호:
FLUKE A283FC EUR
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Product Type

Clamp Meter

Maximum DC Current Measurement

60A

Maximum AC Voltage Measurement

1000V ac

Maximum DC Voltage Measurement

1500V dc

Maximum Resistance Measurement

50mΩ

Model Number

A283FC EUR

DC Voltage Resolution

0.1 V dc

AC Current Accuracy

1.5 %

AC Current Resolution

10mA

DC Current Resolution

10mA

Maximum Jaw Opening

34mm

DC Current Accuracy

1.5 %

AC Voltage Accuracy

1 %

Minimum Operating Temperature

-10°C

Resistance Measurement Accuracy

0.5 %

DC Voltage Accuracy

0.09 %

Clamp Meter Type

Wireless

Maximum Operating Temperature

60°C

Weight

700g

Length

57mm

Height

225mm

Width

105mm

Standards/Approvals

RoHS, CSA, UK CA, CE, ETL

True RMS

Yes

Maximum Conductor Size

34mm

Maximum AC Current Measurement

60A

Safety Category Level

CAT III, CAT IV

Battery Life

150h

Power Source

Battery

Safety Category Voltage

1.5kV

Display Type

LCD

Battery Type

AA Alkaline

COO (Country of Origin):
GB

Fluke Clamp Meter, 34mm Maximum Jaw Opening, 1500V Safety Category Voltage - FLUKE A283FC EUR


This clamp meter is a handheld instrument designed to measure AC and DC electrical parameters safely in industrial and field settings. It provides true-RMS readings for accurate measurement of non-sinusoidal waveforms and incorporates wireless connectivity for remote monitoring. The product operates from AA alkaline cells and meets a range of international safety approvals for use on high-voltage systems.

Features and Benefits:


• True RMS measurement for accurate non-sinusoidal readings
• Measures up to 1500V DC for high-voltage diagnostics
• 1000V AC capability for mains and industrial systems
• 60A measurement with 0.01A resolution for load analysis
• 34mm jaw opening to accommodate larger conductors
• Low resistance measurement down to 50mΩ for continuity checks

Applications


• Suitable for HVAC electricians performing current diagnostics
• Ideal for industrial electrical maintenance on distribution panels
• Used with power-quality assessments on mixed loads
• Can be used for commissioning high-voltage equipment
• Suitable for routine resistance verification in control cabinets

How long will the instrument run between battery changes?


Typical battery endurance is approximately 150h with standard AA alkaline cells under normal use.

What safety classifications allow use on complex installations?


The device is rated for CAT III and CAT IV applications and has been evaluated under multiple certification standards for electrical safety.

What resolution and accuracy can I expect for DC current readings?


DC current readings present a resolution of 0.01A with an accuracy specification suited to precise current-monitoring tasks.

Can the meter resolve small voltage changes for sensitive circuits?


DC voltage detection is provided with 0.1V resolution and a quoted accuracy that supports fine measurement of DC supplies.