Schneider Electric DIN Rail Circuit Trip for use with ISW-NA, iC60 MCB, RCA, IDPN Vigi, Ild Double Terminal, IlD MCB,

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

Subtotal (1 unit)*

₩229,209.60

Add to Basket
수량 선택 또는 입력
재고있음
  • 4 개 단위 배송 준비 완료
  • 추가로 2026년 2월 27일 부터 7 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩229,209.60

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
791-2809
제조사 부품 번호:
A9A26963
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Range

Acti9

Product Type

Circuit Trip

Series

Acti9

For Use With

ISW-NA, iC60 MCB, RCA, IDPN Vigi, Ild Double Terminal, IlD MCB, ARA

Mount Type

DIN Rail

Terminal Type

Clamp

Standards/Approvals

EN/IEC 60947-5-1

Schneider Electric | Acti 9 A9A Series | Auxiliary Contact


Are you looking to add an additional auxiliary contact to your control circuit, to provide further safety? Schneider Electric offers the latest in Auxiliary Contact components and technology.

Specifically, the Acti 9 series of Auxiliary Contactor brings reliability to your circuit by acting as a secondary switching device working in conjunction with other primary devices such as contactors, relays or circuit breakers.

The electrical auxiliaries are combined with iC60 circuit breakers, iID residual current circuit breakers, remote tripping switch disconnector iSW-NA , RCA remote controls and ARA automatic reclosers; they enable tripping or remote indication of their position (open/closed/tripped) upon a fault

Features and benefits:


• Low consumption on your control circuit.

• Compact, lightweight and easily attached to compatible contactors. Clip-on, DIN rail mountable (see datasheet for specifics).

• 18-month manufacturer warranty with Schneider Electric.

• Schneider Green Premium product - easily recyclable and disposed of. Built with sustainability in mind to have the least impact on the environment where possible. Toxic Heavy Metal-free. Mercury free.

Protection ratings & Safety features:

• IP20 conforming to EN/IEC 60947-5-1

Tripping auxiliaries:


iMN: undervoltage release

iMNs: delayed undervoltage release

iMNx: undervoltage release, independant from supply voltage

iMX: shunt release

iMX+OF: shunt release with open/close contact.

Indication auxiliaries:


iOF: open/close contact

iSD: fault indicating contact

iOF/SD+OF: open/close contact and switchable OF or SD contact.

Applications:


• Motor starters/Control systems.;• Switching contactors/relay coils.;• Control/Signalling equipment.

How do Auxiliary Contacts work?


An Auxiliary Contact is an electromechanical device that is mounted typically to contactors. They are physically connected to the contactor, with simultaneous activation and deactivation applying to both of the devices at the same time.

Aux Contacts can be installed onto contactors either by front mounting, or side mounting. This is usually clear in the shape and size of the product, but please check the compatibility of your devices. Aux Contacts are really useful devices to aid in keeping an eye on the contactor.

You can, for example, hook up a low voltage LED directly to the Aux Contactor without having to worry about the overall voltage of the contactor it is linked to (as long the Aux Contactor is electrically isolated from the contactor) you could use the LED to monitor the device i.e. indicate if the motor is off/on.