Energizer CR1220 Button Battery, 3 V, 12.5 mm Diameter

Subtotal (1 unit)*

₩2,300.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 1,759 개 단위 배송 준비 완료
  • 추가로 2026년 10월 12일 부터 1,960 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩2,300.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
108-821
Distrelec 제품 번호:
169-24-387
제조사 부품 번호:
7638900411522
제조업체:
Energizer
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Energizer

Battery Size

CR1220

Product Type

Button Battery

Chemistry

Lithium Manganese Dioxide

Nominal Voltage

3V

Battery Capacity

37mAh

Diameter

12.5mm

Number of Batteries

1

Termination Type

Flat

Weight

800mg

Height

1.8mm

Standards/Approvals

IEC-CR1220, ANSI-5012LC

Series

CR

IEC Code

CR1220

COO (Country of Origin):
CN

Energizer Series CR Button Battery, 3V Nominal Voltage, 37mAh Capacity - 7638900411522


This button battery is a lithium coin cell designed to deliver a Compact 3V power source for small electronic devices. It uses a lithium/manganese dioxide chemistry to provide stable voltage and extended shelf life across a wide temperature range, making it suitable for low-drain and intermittent-duty applications where a thin, flat-termination cell is required.

Features and Benefits:


• 37 mAh nominal capacity provides sustained low-current operation
• 0.8 g weight reduces overall device mass for Compact designs
• Flat termination enables reliable surface contact in tight compartments
• Low self-discharge of ∼1% per year extends storage life
• Operates from -30°C to 70°C for varied environmental use

Applications


• Suitable for small watches requiring Compact power cells
• Used with remote sensors featuring intermittent Pulse drains
• Ideal for memory backup in Compact electronic modules
• Can be used for medical devices with low continuous drain
• Used for key fobs and small security transmitters

What is the expected behaviour under continuous background drain?


With a 45 kΩ continuous load the typical drain is about 0.046 mA, producing long service hours to the 2.0 V cut-off.

How does it perform under pulse-drain conditions?


Simulated pulses of 2 seconds, 12 times per day, yield higher instantaneous current capability while maintaining useful overall capacity.

What limits reverse charging into the cell?


Maximum permissible reverse charge current is 1 μA, keeping the risk of cell damage minimal under small reverse potentials.

What are the energy density values for design calculations?


Energy density is approximately 153 mWh/g and 464 mWh/cc for energy budgeting in Compact systems.