Nuvotem Talema 230V ac, 2 x 15V ac Toroidal Transformer, 225VA 2 Output
- RS 재고 번호:
- 223-8140
- 제조 부품 번호:
- 0225P1-2-015
- 제조업체:
- Nuvotem Talema
본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.
사용할 수 없음
RS는 더 이상 이 제품을 입고하지 않습니다.
대체품
이 제품은 현재 공급 불가입니다. 아래 제품들은 당사에서 추천드리는 대체품입니다.
개당
₩94,426.76
- RS 재고 번호:
- 223-8140
- 제조 부품 번호:
- 0225P1-2-015
- 제조업체:
- Nuvotem Talema
사양
기술적 참조
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Nuvotem Talema | |
| Primary Voltage Rating | 230V ac | |
| Secondary Voltage Rating | 2 x 15V ac | |
| Power Rating | 225VA | |
| Number of Outputs | 2 | |
| Secondary Current | 7.5A | |
| Height | 47mm | |
| Weight | 1.9kg | |
| Diameter | 112mm | |
| Dimensions | 112 (Dia.) x 47mm | |
| Maximum Operating Frequency | 450Hz | |
| Termination Type | Copper Conductor Termination Wire | |
| Minimum Temperature | 0°C | |
| Maximum Temperature | +120°C | |
| Isolation Voltage | 4.5kV ac | |
| 모두 선택 | ||
|---|---|---|
브랜드 Nuvotem Talema | ||
Primary Voltage Rating 230V ac | ||
Secondary Voltage Rating 2 x 15V ac | ||
Power Rating 225VA | ||
Number of Outputs 2 | ||
Secondary Current 7.5A | ||
Height 47mm | ||
Weight 1.9kg | ||
Diameter 112mm | ||
Dimensions 112 (Dia.) x 47mm | ||
Maximum Operating Frequency 450Hz | ||
Termination Type Copper Conductor Termination Wire | ||
Minimum Temperature 0°C | ||
Maximum Temperature +120°C | ||
Isolation Voltage 4.5kV ac | ||
- COO (Country of Origin):
- CZ
Open Style with Leads, 15VA to 1000VA
High-quality open style toroidal transformers with a single 230 Vac 50/60 Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently.
Small size and low weight compared with traditional stacked lamination types
Extremely low level of radiated magnetic field and very low induced noise (hum)
Very low iron losses
Double insulated primary leads
100% electrical and flash tested
High-quality manufacturing and testing in accordance to EN61558, EN60950, EN60065, VDE 0551, VDE 0550 and BS415
Extremely low level of radiated magnetic field and very low induced noise (hum)
Very low iron losses
Double insulated primary leads
100% electrical and flash tested
High-quality manufacturing and testing in accordance to EN61558, EN60950, EN60065, VDE 0551, VDE 0550 and BS415
Standards
UL 506; EN 61558
Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Supplied with
Full mounting kit


Approvals
UL 506; EN 61558
Standards
EN61558; EN60950; EN60065; BS415
Toroidal 230Vac Primary 15VA to 1000VA

