EMERSON – ASCO Solenoid Valve SCE222E002LT.24/50, 2 Port, NC, 24V ac 1/2 in

Subtotal (1 unit)*

₩1,306,383.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 5월 04일 부터 5 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩1,306,383.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
656-3333
제조사 부품 번호:
SCE222E002LT.24/50
제조업체:
EMERSON – ASCO
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

EMERSON – ASCO

Supply Voltage

24V ac

Product Type

Solenoid Valve

Number of Ports

2

Inlet Port Size

1/2 in

Default Valve Position

NC

Orifice Diameter

16mm

Body Material

Brass

Series

222LT

Application

Cryogenic Liquid

Minimum Operating Temperature

-20°C

Maximum Operating Pressure

9 bar

Maximum Operating Temperature

50°C

Standards/Approvals

No

Hazardous Area Certification

NO

Maximum Closing Time

100ms

Flow Factor Kv

3.3m³/h

Maximum Opening Time

100ms

제외

222 LT series 2 / 2 assisted control solenoid valves


2 / 2 N/C assisted control, hung piston solenoid valves for cryogenic service.

Solenoids with two orifices for heavy-duty systems and compatible pressurised fluids.

For use with fluids at low pressure and high flow rate.

Do not require a minimum operating pressure.

Valves are degreased, tested and packed to keep them free from moisture.

Liquid oxygen valves are UV-light tested to check for any hydrocarbons.

Valves are constructed as a drawn seamless stainless steel core tube to ensure sealed separation of electrical parts and the fluid controlled.

These solenoid valves must be mounted vertically with the magnetic head upright.

Pluggable connectors.

Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.

Standards

ISO 4400 - IEC 335

관련된 링크들