Eaton MTL Series Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 18 → 32V dc Supply
- RS 제품 번호:
- 144-8694
- 제조사 부품 번호:
- MTL1249
- 제조업체:
- Eaton
가격 개당**
₩366,875.60
18 <재고있음> 5-9영업일내 홍콩 발송*
* 배송 날짜는 선택한 수량과 배송 주소에 따라 달라질 수 있습니다.
수량 | 한팩당 |
---|---|
1 + | ₩366,875.60 |
**다른 단위에 대한 가격 표시
- RS 제품 번호:
- 144-8694
- 제조사 부품 번호:
- MTL1249
- 제조업체:
- Eaton
- COO (Country of Origin):
- GB
Eaton MTL1249 Signal Converter
MTL1249 is a 1 channel signal conditioner that accepts voltage or current inputs and provides a voltage or current output. The signal levels are selected when using switches on the module. The signal conditioner is DIN Rail mountable.
Features and Benefits
1 Channel voltage/current signal converter
Power supplied via power bus embedded in the DIN Rail
DIN Rail mounting
Power supplied via power bus embedded in the DIN Rail
DIN Rail mounting
Eaton MTL Analogue Signal Conditioner, 18 to 32V DC Supply Voltage, 0 to 20mA Output - MTL1249
This signal conditioner from Eaton converts analogue signal inputs into more easily readable analogue signal outputs. It's suitable for use with both voltage and current inputs and outputs. Devices of this type are used in industrial process control and instrumentation and testing applications. You can easily select the signal levels via the switches on the device. It draws its power directly from a power bus on a DIN rail without the need for complex wiring systems. As the unit has an almost instant response time of 20 milliseconds, so there's no delay in signal conversion. This device offers isolation between power, field and system circuits to ensure a high level of electrical safety.
Features & Benefits
• Wide operating temperature range of -20°C to +60°C, for compatibility with industrial environments
• Screw terminals ensure a secure connection with wires
• Transfer accuracy of 0.2% for precise signal conditioning and improved reliability
• Screw terminals ensure a secure connection with wires
• Transfer accuracy of 0.2% for precise signal conditioning and improved reliability
Why can't signals from a sensor be sent directly to a control circuit?
The electronic signals detected by devices like sensors and temperature monitors are often completely different due to the variation in data measurement. This makes it difficult to input the data directly into control circuits without converting it into a readable form.
Note
Eaton formerly known as MTL
MTL Signal Conditioners
속성 | 값 |
---|---|
Module Type | Analogue Signal Converter |
Input Signal Type | Current, Voltage |
Output Signal Type | Current, Voltage |
Input Range | 0 → 1 V, 0 → 10 V, 0 → 100 mV, 0 → 2 mA, 0 → 5 V, 1 → 5 V, 4 → 20mA |
Output Range | 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20mA |
Supply Voltage | 18 → 32V dc |
Mounting Type | DIN Rail Mount |
Operating Temperature Range | -20 → +60°C |
Series | MTL |
Maximum Operating Temperature | +60°C |
Minimum Operating Temperature | -20°C |
Termination | Screw |