Schmersal Dual-Channel Light Beam/Curtain, Safety Switch/Interlock Safety Relay, 24V ac, 3 Safety Contacts
- RS 제품 번호:
- 741-8657
- 제조사 부품 번호:
- SRB302X3-24VAC/DC-230VAC
- 제조업체:
- Schmersal
10 <재고있음> 5-9영업일내 홍콩 발송
단가 개당
₩595,913.277
수량 | 한팩당 |
---|---|
1 + | ₩595,913.277 |
- RS 제품 번호:
- 741-8657
- 제조사 부품 번호:
- SRB302X3-24VAC/DC-230VAC
- 제조업체:
- Schmersal
참조 문서
제정법과 컴플라이언스
- COO (Country of Origin):
- DE
제품 세부 사항
Schmersal Dual-Channel Safety Relay, 24V AC/DC, 230V AC - PROTECT SRB 302X3 Series - SRB302X3-24VAC/DC-230VAC
The PROTECT series of Safety Relays from Schmersal, specifically the SRB302X3s are known for their reliability and durability in the field.
Features and benefits
• Suitable for signal processing of potential free outputs (examples being emergency stop buttons, position switches or solenoid interlocks).
• Suitable for signal processing of outputs connected to potentials (AOPDS) for example safety light grids/curtains
• Safety contacts ranging from 3 onwards
• Signalling outputs ranging from 2 onwards
• Snap on DIN rail mounting as standard with this product allowing easy additions & removals, allowing you the flexibility and portability you require.
• Suitable for signal processing of outputs connected to potentials (AOPDS) for example safety light grids/curtains
• Safety contacts ranging from 3 onwards
• Signalling outputs ranging from 2 onwards
• Snap on DIN rail mounting as standard with this product allowing easy additions & removals, allowing you the flexibility and portability you require.
Applications
• Emergency stop buttons
• Security guards
• Emergency pull switches by cable traction
• Safety light curtain
• Security guards
• Emergency pull switches by cable traction
• Safety light curtain
Advantages of the SRB302X3
• 20 year mission time for this device, giving you the confidence in the quality of the build
• Compact in design allowing you more mounting on your DIN rail or equivalent
• Low power consumption compared to other units on the market
This safety relay is relatively maintenance-free. However, you should occasionally check the power cable for damage to ensure safe operation.
Technical safety parameters
• EN 954-1 Category - Cat 4
• EN ISO 13849-1 Performance Level – Ple
• EN 62061 SIL Claim - SIL CL 3
• EN ISO 13849-1 Performance Level – Ple
• EN 62061 SIL Claim - SIL CL 3
사양
속성 | 값 |
---|---|
Supply Voltage | 24 V ac/dc, 230V ac |
Number of Channels | 2 |
Safety Contacts | 3 |
Function | Light Beam/Curtain, Safety Switch/Interlock |
Auxiliary Contacts | 2 |
Reset Method | Automatic |
Range | PROTECT |
Safety Category ISO 13849-1 | 4 |
PL ISO 13849-1 | e |
SIL IEC 61508 | 3 |
Terminal Type | Screw |
Standards Met | IEC60947-1 |
Series | SRB 30X3 |
Depth | 121mm |
Width | 45mm |
Performance Level | e |
Length | 100mm |