Pilz PSWZ X1P, 24V ac/dc, 240 V ac/dc Safety Relay, 2 Safety Contacts, 1

Subtotal (1 unit)*

₩1,100,443.50

Add to Basket
수량 선택 또는 입력
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량
한팩당
1 +₩1,100,443.50

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
489-6394
Distrelec 제품 번호:
304-23-246
제조사 부품 번호:
777949
제조업체:
Pilz
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Pilz

Product Type

Safety Relay

Safety Contacts

2

Number of Auxiliary Contacts

1

Mount Type

DIN Rail

Power Consumption

5VA

Series

PSWZ X1P

Terminal Type

Screw

IP Rating

IP20

Standards/Approvals

RoHS

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

55°C

Width

45mm

Height

121mm

Length

94mm

Hazardous Area Certification

No

Safety Category

PLe Category 4

Coil Voltage

24, 240V ac/dc

COO (Country of Origin):
FR

PSWZX1P Safety Relay by PILZ


The PSWZX1P range of safety relays from PILZ offers you safety and performance all in one. The PSWZX1P offers you different modes of operation such as single or dual channel switches. Suitable specifically for operating your safe standstill machinery or tools that are deemed dangerous or hazardous to health.

Features and benefits:


• DIN rail mounted with screw terminals

• LED display that offers you the following measures:

- Supply voltages

- Standstill on Channel 1 / 2

- Switch status

- Fault signal if simultaneity time is exceeded

• Semiconductor output signal (input for reset function):

- Error

- Switch status

• Measure inputs for single or three-phase motors

• Measuring voltage is selectable

• Feedback loop is in operation

• Plug in connection terminals is possible

Safety features:


• Relays K1 & K2 are interlocked specifically designed so that the unit cannot be switched back on in the case of contact welding or an open circuit (ensuring your safety at all times)

• The unit will monitor and measure and look out for an open circuit. If the circuit does open, the unit will immediately switch itself off to prevent hazards

• The standstill motor which is unique to the PSWZ X1P prevents the plant from being enabled, in the following cases:

- Power supply failure

- Component failure

- Measuring circuits are open circuit

- Coil deflect / open circuit

Applications:


Safe standstill monitoring – this is the units main purpose and is specifically designed for safe standstill where areas of operation such as plants have dangerous machinery or tools in use. Safe standstill monitoring is only detected on power free measuring circuits. Any residual voltages, induced voltages or drives with in the position control will prevent the relay from its main function so take this into consideration when in use

Technical safety parameters:

• EN 60204-1
• EN 62061
• EN ISO 13849-1
• EN ISO 14119
• VDE 0113-1


Approvals

BG, UL, CUL

Standards

VDE 0113; EN 60204-1; IEC 204-1