SICK Inductive Threaded Barrel Proximity Sensor, M5, 1 mm Detection, PNP NO, 10 → 30 V dc

Subtotal (1 unit)*

₩644,182.00

Add to Basket
수량 선택 또는 입력
현재 액세스할 수 없는 재고 정보
수량
한팩당
1 +₩644,182.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
266-8594
제조사 부품 번호:
IMP05-01BPSVU2S
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Thread Size

M5

Sensor Technology

Inductive

Body Style

Threaded Barrel

Detection Range

1 mm

Digital Switching Output Type

PNP

Output Function

NO

Cable Length

2m

Connection Type

Pre-Cabled

Supply Voltage

10 → 30 V dc

IP Rating

IP68

Length

27mm

Mounting Type

Flush

Width

5mm

Housing Material

Phynox

Maximum DC Voltage

30V

Minimum Operating Temperature

-25°C

Reverse Polarity Protection

Yes

Switching Current

200 mA

Maximum Switching Frequency

4.8kHz

Shielding

Shielded

Short Circuit Overload Protection

Yes

Series

IMP

Standards Met

CE, EAC

Maximum Operating Temperature

+70°C

Switching Frequency

4.8 kHz

COO (Country of Origin):
LK

Overview


The inductive, high-pressure-resistant IMP sensors are perfectly suited for the query of end positions in hydraulic cylinders. The use of state-of-the-art ASIC and manufacturing technologies from SICK sets new standards in installation size, service life and load capability for the sensors. Due to the stable stainless steel housing and an active high-performance ceramic surface, they are pressure-resistant up to 500 bar.

Above-average system throughput is a matter of course for the range of models M5, M8, M12 andM14 thanks to 1 million tested pressure cycles.

At a glance


Types: M5, M8, M12 and M14
Extended sensing ranges: 1 mm to 3 mm
Electrical configuration: DC 3- and 4-wire
Enclosure rating: IP 68
Temperature range: –25 °C to +100 °C
Stainless steel housing with active surface made from stable high-performance ceramic
Pressure resistant up to 500 bar, gas-tight front
Expected service life of up to 1 million pressure cycles

Your Benefit


Reduced maintenance costs
Extremely resilient and durable
Up to 50 times longer service life compared to conventional sensors under pressure cycles
Simple compensation of cylinder tolerances
Simple integration due to small design
Controlled piston deceleration
Increased piston service life due to collision prevention at the end of the work cycle

Applications


End position detection of a piston stroke in hydraulic cylinders

Note