Fluke A3001 FC Clamp Meter 2500 A CAT IV, CAT III Non-Contact Voltage Detector

Subtotal (1 unit)*

₩643,831.50

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 7월 03일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩643,831.50

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
811-1331
Distrelec 제품 번호:
110-83-817
제조사 부품 번호:
FLK-A3001 FC
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Product Type

Clamp Meter

Model Number

A3001 FC

Maximum Jaw Opening

254mm

AC Current Resolution

100mA

AC Current Accuracy

±3 % rdg + 5 Digits

Minimum Operating Temperature

-10°C

Clamp Meter Type

AC Current Clamp Meter

Maximum Operating Temperature

50°C

Length

14mm

Height

165mm

Width

63.5mm

Standards/Approvals

No

Weight

220g

Functions Measured

AC Current

True RMS

Yes

Non-Contact Voltage Detector

Yes

Maximum AC Current Measurement

2500A

Battery Type

AA

Safety Category Voltage

1000V

Safety Category Level

CAT IV, CAT III

Battery Life

400h

Display Type

LCD

Power Source

Battery

제외

COO (Country of Origin):
CN

Fluke Clamp Meter, 2500A Maximum AC Current Measurement, 254mm Maximum Jaw Opening - FLK-A3001 FC


This clamp meter is a wireless true‑RMS iFlex current module designed to relay AC current measurements to compatible Master units and mobile devices. It is intended for field and workshop use where remote monitoring, flexible conductor access and extended logging are required, operating across typical industrial temperature and humidity ranges.

Features & Benefits


• Measures up to 2500 A for high‑current system diagnostics
• Accuracy of ±3% rdg + 5 digits for precise readings
• 254mm jaw opening with flexible Coil for awkward conductors
• 400 h battery life using two AA cells for long deployments
• Built‑in non‑contact voltage detector to enhance site safety
• True RMS measurement to handle non‑sinusoidal loads

**Applications**


• Suitable for motor start‑up and inrush current analysis
• Ideal for measurements on busbars and large conductors
• Used with mobile devices to view live remote readings
• Can be used for preventative maintenance logging sessions
• Suitable for power distribution fault finding in plants

What logging capability is available for recording sessions?


It can Record up to 65,000 time‑stamped readings, with adjustable log intervals from 1 s to 1 hr when configured via PC or the front panel.

How does it communicate measurements to other equipment?


Wireless RF at 2.4 GHz transmits live data up to 20m in unobstructed conditions and shorter ranges through walls or enclosures.

What environmental limits affect operation?


It operates between −10 °C and +50 °C and supports high humidity profiles decreasing with temperature, with storage from −40 °C to +60 °C.

Which power source and lifespan should users expect in the field?


The unit is powered by two AA alkaline cells and provides approximately 400 h of operation under typical conditions.