Siemens LOGO! Series I/O module for Use with LOGO! 8, LOGO! 8.2, 12 → 24 V dc Supply, 2-Input, Analogue

Subtotal (1 unit)*

₩186,646.40

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2025년 12월 08일 부터 105 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩186,646.40

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
825-1697
Distrelec 제품 번호:
110-95-456
제조사 부품 번호:
6ED1055-1MD00-0BA2
제조업체:
Siemens
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Siemens

Manufacturer Series

LOGO!

Number of Inputs

2

For Use With

LOGO! 8, LOGO! 8.2

Supply Voltage

12 → 24 V dc

Input Type

Analogue Pt100/1000

Programming Interface

Computer

Width

35.5mm

Maximum Operating Temperature

+55°C

Minimum Operating Temperature

0°C

Number of Analogue Inputs

2

Depth

58mm

Standards Met

CE, CSA, FM

Dimensions

90 x 35.5 x 58 mm

Mounting Type

DIN Rail

Length

90mm

COO (Country of Origin):
CN

Siemens I/O Module For Use With LOGO! 8 and LOGO! 8.2 Series, Analogue, PT100/1000 Input Type - 6ED1055-1MD00-0BA2


This I/O module from Siemens expands the capability of your PLC. It uses analogue PT100/1000 connections to feed readings from temperature sensors to your controller, letting your automated system respond to temperature changes. The unit has two input ports to monitor multiple measuring appliances at once, allowing you to build an efficient control setup. For safe handling, an IP20 rating indicates the module is protected against objects over 12mm, meaning your fingers can't touch live parts. As the component only consumes between 15 and 30mA of current, it maintains your application's energy efficiency. And by supporting voltages between 12 and 24V DC, it works with common power supplies.

• Mounts on a DIN rail for fast installation
• Front-facing LED indicator lights provide quick diagnostic information
• Dimensions of 35.5 (width) x 90 (height) x 58mm (depth) make for easy mounting in busy systems
• Operating temperature range between 0°C and +55°C to perform in harsh conditions

Should I use two-wire or three-wire connections with this input module?


If obtaining reliable readings is your priority, use three-wire sensor connections. While two-wire connections save wiring time, three-wire connections provide more accurate data.

관련된 링크들