Unipower 8A HPL Motor Load Monitor, 380V, 440 V, 50 °C, -15 °C

Subtotal (1 unit)*

₩847,600.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 44 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩847,600.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
245-5941
제조사 부품 번호:
HPL110.380-440
제조업체:
Unipower
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Unipower

Product Type

Motor Load Monitor

Current Rating

8A

Motor Protection Component

Load Monitor

Supply Voltage

380V, 440V

Motor Protection System

Motor Condition Monitoring Device

Series

HPL

Overall Length

56mm

Overall Width

75mm

IP Rating

IP20, IP40

Overall Depth

110mm

Minimum Operating Temperature

-15°C

Maximum Operating Temperature

50°C

Standards/Approvals

EN61010-1, EN61326-1, UL 508

제외

COO (Country of Origin):
DK

Digital Motor Load (kW) Monitors


Units which measure true motor load in kW featuring a digital display of kW% and programmable trips for over and/or under load events.These units protect equipment from damage caused by the motor running against a jam, blockage or under load and are also used in processes to trigger subsequent actions when predetermined load levels are reached (end point monitoring).The display is used as a reference enabling motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons.The units are usually mounted in the motor control panel and are connected to a convenient point on the motor supply (before Inverter - if used).Therefore no external field wiring or sensors in the equipment are necessary.

In addition to displaying motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up and fault diagnosis.Three digital delay timers, programmable from 0.1-25 seconds are incorporated to time out motor start surge and short duration over and under power events which could cause nuisance tripping.A DIP switch is used to tamper proof all settings. The HPL110 and HPL110A can be switched to either 50 or 6necessary.In0Hz operation.Both units can be operated in manual or auto-reset modes. In auto-reset mode programmable hysteresis, which provides differential between trip and reset levels is automatically enabled.The HPL 110 is DIN rail mounting whilst the HPL110A can be panel mounted.Applications include the over/underload protection of:Pumps (dry run, closed valve), Fans (broken belt, closed damper), Conveyors (screw and belt),Separation screens, Macerators, scrapers, Mechanical drives (gearboxes, chains)