Dold Monitoring Relay, 3 Phase, SPDT, DIN Rail, 110V ac, 230 V ac 24 V dc

Subtotal (1 unit)*

₩957,372.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 6월 08일 부터 2 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩957,372.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
445-9074
제조사 부품 번호:
BH9097.38/001 3AC400V AC40A
제조업체:
Dold
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Dold

Product Type

Monitoring Relay

Electrical Phase

3

Function

Motor Control

Contact Configuration

SPDT

Mount Type

DIN Rail

Switching Voltage

230V ac

Terminal Type

Screw

IP Rating

IP20, IP40

Supply AC Voltage

110, 230V ac

Contact Current

5A

Minimum Operating Temperature

-20°C

Supply DC Voltage

24 V dc

Maximum Operating Temperature

55°C

Height

84mm

Series

BH 9097

Width

45mm

Standards/Approvals

IEC/EN 61 000-4-2, EN 50 005, IEC/EN 61 000-4-6, IEC/EN 60 529, EN 55 011, DIN 46 228-1/-2/-3/-4, IEC/EN 60 068-2-6, IEC/EN 60255-26, IEC/EN 61 000-4-4, DIN/VDE 0435-303, IEC/EN 60 947-5-1, IEC 60 664-1, UL Subject 94, IEC/EN 61 000-4-5, IEC/EN 61 000-4-3, IEC/EN 60255-1, IEC/EN 60 068-1, IEC/EN 60 715

Length

121mm

COO (Country of Origin):
DE

Load monitor BH 9097


The load monitor is suitable for monitoring electrical industrial drive systems with variable motor loads.

Features:


The BH 9097 load monitor monitors the actual power consumption of electrical loads

The device can be configured via DIP switches for negative load and overload monitoring or for overload monitoring with preliminary warning level

P1 and P2 settings are calibrated as absolute values; configuration via two rotary switches

Test / reset buttons for simple start-up

Switch state indicator via 2 LEDs

For motors up to 22 KW at 3 AC 400 V, without auxiliary voltage

Up to 40 A without external current transformer

Configurable start-up bridging, configurable response delay

Overall width 45 mm

Load monitor


Using the load monitor allows all machines that are driven by electric motors to be monitored securely. This load monitor can be used for early detection of damage to the bearings or gear, blockage or idling of the screw-conveyors or conveyor belts, as well as V-belt failures or filter blockages, in order to prevent more severe damage or machine failures.

The Telehaase load monitor does not require additional sensors or transducers. It can be used without a current transformer from 230 to 6930 W. Even when operating a frequency inverter, monitoring tasks are completed easily. With all load monitors, start-up bridging and a switching delay can be calibrated.

Standards

IEC 255, EN 60255, VDE 0435 part 303