Fluke 922/KIT Differential Manometer Kit With 2 Pressure Port/s, Max Pressure Measurement 10 psi

Subtotal (1 unit)*

₩1,947,894.00

Add to Basket
수량 선택 또는 입력
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량
한팩당
1 +₩1,947,894.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
287-636
Distrelec 제품 번호:
176-60-392
제조사 부품 번호:
FLUKE 922/KIT
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Product Type

Manometer Kit

Accuracy

±1% +0.01 mbar

Number of Pressure Ports

2

Maximum Pressure Measurement

10psi

Minimum Pressure Measurement

0mbar

Pressure Port Type

Differential

Minimum/Maximum Recordings

Yes

Model Number

922/KIT

Data Logging

Yes

IP Rating

IP40

Power Source

4 AA Batteries

Minimum Operating Temperature

0°C

Battery Type

AA

Maximum Overpressure

10psi

Maximum Operating Temperature

50°C

Battery Life

280, 60h

Display Type

LCD

Length

41.9mm

Width

77.5mm

Standards/Approvals

CE

Height

175mm

Hazardous Area Certification

NO

Weight

640g

제외

COO (Country of Origin):
TW

Fluke Manometer Kit, ±1 % rgd Accuracy, IP40 - FLUKE 922/KIT


This manometer kit is a handheld instrument for measuring differential and static pressure, Airflow and Air velocity in HVAC and industrial environments. It combines a micromanometer with colour‑coded hoses and a backlit LCD to aid clear readings on site, powered by AA batteries and supplied with a rugged holster and wrist strap for field use.

Features & Benefits


• Differential range to 10psi with ±1% rgd+0.01mbar accuracy provides precise pressure data
• Data logging stores up to 99 readings for later analysis
• Air velocity span to 16,000fpm enables broad duct measurements
• Temperature measurement from 0°C to 50°C supports environmental checks
• Resolution to 0.001inH2O captures fine pressure changes
• IP40 enclosure and robust housing withstand typical site conditions

**Applications**


• Suitable for measuring pressure drops across HVAC components
• Ideal for performing duct traversals to calculate airflow volume
• Used for monitoring indoor versus outdoor pressure relationships
• Can be used to match ventilation to occupant loads
• Used with building fabric assessments to manage airflow and comfort

What power options and runtimes are available for fieldwork?


The instrument operates from four AA batteries, delivering approximately 280 hours without the backlight and around 60 hours with the backlight active.

How many pressure connections does it offer and what type are they?


It includes two pressure ports configured for differential measurements and accepts a maximum overpressure of 10psi at each port.

What storage and environmental limits apply to the instrument?


Readings can be saved in internal memory up to 99 points

operating temperature is 0°C to 50°C and storage ranges from −40°C to +60°C with relative humidity up to 90% non‑condensing.

Which standards and approvals relate to its use in professional settings?


The unit meets CE requirements and electromagnetic compatibility standards in EN61326‑1, and vibration resilience to MIL‑PRF‑28800F Class 3.

Supplied with

Fluke 922 - two rubber hoses, wrist strap, 300mm Pitot tube, ToolPack hanging kit, hard carry case, 4 x AA Batteries and manual

관련된 링크들