- RS 제품 번호:
- 323-5906
- 제조사 부품 번호:
- 280-681
- 제조업체:
- Wago
15 <재고있음> 5-9영업일내 홍콩 발송
705 <재고있음> 5-9영업일내 홍콩 발송
추가완료!
단가 개당가격(5개가 1팩안에)
₩6,211.365
수량 | 한팩당 | 한팩당* |
5 + | ₩6,211.365 | ₩31,056.825 |
*다른 단위에 대한 가격 표시 |
- RS 제품 번호:
- 323-5906
- 제조사 부품 번호:
- 280-681
- 제조업체:
- Wago
제정법과 컴플라이언스
- COO (Country of Origin):
- DE
제품 세부 사항
Wago Feed-Through Terminal Block, 0.766W Power Loss, 800V Voltage Rating - 280 Series - 280-681
Carry signals safely to your DIN rail-connected components with this feed-through terminal block from Wago. Its three-contact configuration gives you multi-circuit control, reducing your setup's wiring needs and enabling a clutter-free design. The unit's PA housing does double duty, offering impact protection for use in harsh environments and insulation to keep electrical hazards at bay. Thanks to compact dimensions of 64 (H) x 5 (W) x 28mm (D), there's no issue installing it in networks with limited space. A current rating of 24A means this terminal block is the right choice for heavy-duty applications.
Features & Benefits
• Stops burning in 10 seconds or less in the event of a fire, reducing the spread of flames
• Cage clamp termination method doesn't need complex tools, saving time and hassle
• Suitable for use in demanding environments, thanks to a broad operating temperature range between -60°C and +105°C
• Cage clamp termination method doesn't need complex tools, saving time and hassle
• Suitable for use in demanding environments, thanks to a broad operating temperature range between -60°C and +105°C
Applications
• Medical equipment
• Water treatment plants
• Transportation industry
• Water treatment plants
• Transportation industry
What tool do I need to link wires to this terminal block?
To connect conductors to this unit, all you need is a screwdriver.
280 Series
사양
속성 | 값 |
---|---|
Colour | Grey |
Number of Levels | Single |
Series | 280 |
American Wire Gauge | 28 → 12AWG |
Termination Method | Cage Clamp |
Cable CSA | 2.5mm² |
Fused | No |
Current Rating | 24A |
Voltage Rating | 800 V |
Minimum Operating Temperature | -60°C |
Maximum Operating Temperature | +105°C |
Standards Met | CSA |