Eaton xStart DILM Contactor, 400 V ac Coil, 3-Pole, 7 A, 3 kW, 1NC, 400 V ac
- RS 제품 번호:
- 743-4889
- 제조사 부품 번호:
- 276587 DILM7-01(400V50HZ,440V60HZ)
- 제조업체:
- Eaton
가격 개당**
₩70,088.20
9 <재고있음> 5-9영업일내 홍콩 발송*
* 배송 날짜는 선택한 수량과 배송 주소에 따라 달라질 수 있습니다.
수량 | 한팩당 |
---|---|
1 + | ₩70,088.20 |
** 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 743-4889
- 제조사 부품 번호:
- 276587 DILM7-01(400V50HZ,440V60HZ)
- 제조업체:
- Eaton
DILM Contactors, 3 Phase
X Start is the latest generation of Contactors, Overloads and Relays from Moeller, based on the tried and tested DIL series. This generation of modular components benefits from the advances in technology for motor switching and control, which in turn gives the user a number of additional benefits.
Features & Benefits
All the contactors are modular and have a common design
The range is extremely durable, able to handle all demands and features immunity to interference and control circuit reliability-even when used in conjunction with PLCs
Electronic power adjustment of the magnet system on the DC contactors enables very small frame sizes so that AC and DC units now have identical dimensions. This now allows direct arrangement of AC and DC contactors beside each other
The range is extremely durable, able to handle all demands and features immunity to interference and control circuit reliability-even when used in conjunction with PLCs
Electronic power adjustment of the magnet system on the DC contactors enables very small frame sizes so that AC and DC units now have identical dimensions. This now allows direct arrangement of AC and DC contactors beside each other
Typical Applications
Three normally-open main contacts
DC contactors from 12A have an electronic drive that removes the need for coupling relays and all DC contactors up to 150A have a in-built suppressor circuit
Box terminals with double coupling areas gives a guaranteed integrity of connection while wiring different cross-sections and also reduces cabling faults
DC contactors from 12A have an electronic drive that removes the need for coupling relays and all DC contactors up to 150A have a in-built suppressor circuit
Box terminals with double coupling areas gives a guaranteed integrity of connection while wiring different cross-sections and also reduces cabling faults
This range of contactors can be used across a multitude of applications, users will commonly find these contactors being used within industrial settings such as factory automation, railway transportation, electrical systems, electric motor, lighting, and mechanical engineering.
How contactors operate?
Contactors, unlike relays, are specifically designed to connect to high current load devices. Used in larger-scale applications, a contactor is a switch that can be controlled remotely, specifically designed to switch a large amount of electrical power through its contacts. If a device has the ability to switch more than 15 amperes it is called a contactor. These devices also feature high coil voltages which is rare within relays.
Eaton DILM Series Contactor, 400V AC Coil Voltage, 3NO Normal State Configuration - 276587 DILM7-01(400V50HZ,440V60HZ)
This contactor plays a key role in electrical systems by efficiently controlling motor loads. Operating at 400V AC and capable of managing up to 7A of current, it is suitable for a variety of automation applications. Its reliable performance and straightforward installation enhance its utility in both industrial and commercial settings.
Features & Benefits
Coils not replaceable
Applications
• Used with compressors for effective motor control
• Suitable for lifts, enhancing safety and performance
• Employed in fans and pumps for dependable operation
• Ideal for conveyor belts in manufacturing processes
• Utilised in air conditioning systems for reliable functionality
• Suitable for lifts, enhancing safety and performance
• Employed in fans and pumps for dependable operation
• Ideal for conveyor belts in manufacturing processes
• Utilised in air conditioning systems for reliable functionality
What is the maximum operational temperature for this device?
The maximum operating temperature is +60°C, ensuring effective performance in different environments.
How many auxiliary contacts are available with this model?
This model includes one normally closed auxiliary contact, which improves operational flexibility.
Can it be used for any type of motor?
It is specifically designed for AC motors, making it appropriate for various applications.
What tools are required for installation?
A Pozidriv screwdriver (Size 2) and a standard screwdriver (0.8 x 5.5mm) are recommended for installation.
Note
Eaton formerly known as Moeller
속성 | 값 |
---|---|
Coil Voltage | 400 V ac |
Number of Poles | 3 |
Contact Voltage Rating | 400 V ac |
Contact Current Rating | 7 A |
Power Rating | 3 kW |
Series | DILM |
Range | xStart |
Normal State Configuration | 3NO |
Number Of Auxiliary Contacts | 1 |
Terminal Type | Screw |
Length | 75mm |
Width | 45mm |
Depth | 75mm |
Control Voltage | 400/440 V ac |
Pole and Throw Configuration | 3P |
Minimum Operating Temperature | -25°C |
Maximum Operating Temperature | +60°C |